36
Step 4.
A
NC
(normal close)
/
NO
(normal
open) option is required to choose.
o N C
N O v
<
<
N
N
O
O
T
T
E
E
>
>
)
NC:
The wired siren/light activates in
normal.
)
NO:
The wired siren/light deactivates
in normal.
<
<
E
E
X
X
A
A
M
M
P
P
L
L
E
E
>
>
)
If Burglar (attribute) and
NO
is set for
a wired siren/light, and when an alarm
is triggered, the siren/light will close.
)
If AUX (attribute) and
NO
is set for a
Remote Controller, and when the
Remote Controller’s panic button is
pressed & held for 3 seconds, the
wired siren/light will switch to
NC
for 1
second then switch back to
NO
.
Step 5.
Choose whether you wish to have the
wired siren/light set to Normal Open or
Close.
2.5. Common. Setting
o A u t o - c h e c k - i n
O f f s e t p e r i o d
S u p e r v i s i o n
L a t c h s e l e c t
A
r e a S
o
u
n
d
S M S P - Wo r d
R C E n t E s e l .
2.5.1. Auto-Check-In
This is to select whether the Control Panel
needs to do check-in reporting to the Central
Station automatically and to select the period of
time between check-in reports. Options
available are
Disable
,
15 Min, 30 Min, 1 Hr…
up to 4 Weeks
.
o D i s a b l e
1 5 M i n
3 0 M i n
-
-
-
-
3 We e k s
4 We e k s
z
1Day
is set as factory default.
2.5.2. Offset Period
This is to set the time delay before the first
Auto Check-In
report to be made.
After power is supplied or re-supplied to the
Control Panel, a test report will be sent to the
Central Monitoring Station (CMS) based on the
Offset Period. This is used to test whether the
CMS is able to receive the report from the
Panel accurately.
After this test report is sent, the Control Panel
will then send regular reports based on the
setting of the Auto Check-in Report.
For example, if
Offset
Period
is set to 2 Hours,
and
Auto Check-in Report
is set to 3 Days,
the Control Panel will transmit an event code
602 to the CMS after 2 hours, and then report
602 event code periodically at a regular
intervals of 3 days.
Options available are
1 Hour, 2 Hours… to 12
Hours
in 1-hour increments.
o 1 H o u r
2 H o u r s
3 H o u r s
-
-
-
1 2 H o u r s
z
1 hr
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
Off-set period will reset each time after
entering the Offset menu.