29
Single area
means that BX-15 raises
an alarm only when the sensor, which is
learnt in this area, is triggered.
Whole system
means that BX-15
raises an alarm when any sensor,
which is learnt in either Area 1 or Area 2,
is triggered.
Step 7.
Select either Single Area or Whole
System and press
OK
key to confirm
and to send an acknowledgement to
BX-15. BX-15 will emit a short beep
with LED 1&3 flashing once, to
indicate that the learning process is
successful.
<
<
N
N
O
O
T
T
E
E
>
>
)
Steps 5-7 should be finished within the
15-sec waiting period; otherwise the
BX-15 LED dims and the learning
process fails.
)
If the learning process fails, please
remove the BX-15 learning memory
from the control panel and repeat
steps 3-7.
Step 8.
Slide SW1 on BX-15 to OFF position.
BX-15 leaves learning mode.
Step 9.
On the other hand, after step 7, the
Control Panel requires you to program
the sensor zone number.
Step10
. Select the zone number and press
OK
key to confirm. Another prompting
message will be displayed for
selecting its zone name.
Step 11.
Press
OK
key to confirm the zone
number and learning process.
Indoor Siren (SR-15)
Step 1.
Release the screws at the bottom of
SR-15 and pull the outer case out
carefully. Locate the Function Switch
Block.
Step 2.
Use a sharp object to slide DIP SW3 &
SW4 on SR-15 function switch block
for your desired alarm period (see
operation manual of SR-15).
Step 3.
Put the Control Panel into
/-
menu and select the
Add Devices
submenu. The screen on Control
Panel shows “
À
Push button on
À
Device to add”.
Step
4.
Slide DIP SW1 on SR-15 function
switch block to ON position. SR-15 will
emit a short beep and enters learning
mode.
Step
5.
Press SR-15 Tamper Switch once to
transmit learning code. SR-15 will
beep once and start a 15-sec waiting
period for receiving the
acknowledgement from the Control
Panel.
Step
6.
If the Control Panel receives the
learning signal, the screen displays:
D e t e c t e d : ( O K ? )
S R 1 5
Press
OK
key to confirm. The screen
displays:
S i n g l e a r e a
Wh o l e s y s t e m
Single area
means that SR-15 raises
an alarm only when the sensor, which is
learnt in this area, is triggered.
Whole system
means that SR-15
raises an alarm when any sensor,
which is learnt in either Area 1 or Area 2,
is triggered.
Step
7.
Select either Single Area or Whole
System and press
OK
key to confirm
and to send an acknowledgement to
SR-15. SR-15 will emit two short
beeps to indicate that the learning
process is successful.
<
<
N
N
O
O
T
T
E
E
>
>
)
Steps 5-7 should be finished within the
15-sec waiting period; otherwise SR-
15 beeps once and the learning
process fails.
)
If the learning process fails, please
remove the SR-15 learning memory
from the control panel and repeat
steps 3-7.
Step 8.
Slide DIP SW1 on the SR-15 to OFF
position. SR-15 leaves learning mode.
Step 9.
On the other hand, after step 7, the
Control Panel requires you to program
the sensor zone number.