After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a
Burglar Alarm
after 30 secs
and an event code
131
will be reported.
z
When the system is in Alarm off mode,
if an
Entry
Door Contact is triggered,
the Control Panel will make a ding-
dong sound for Door Chime (if
programmed). To program Door
Chime, please refer to section 2.3.3.9.
)
P for
Away Entry
Door Contact
z
When the system is in Away arm
mode, if an
Away Entry
Door Contact
is triggered, the Control Panel will
start an entry period to give enough
time to disarm the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a
Burglar Alarm
after 30 secs and an event code
131
will be reported.
z
When the system is in Alarm off mode,
if an
Away Entry
Door Contact is
triggered, the Control Panel will make
a ding-dong sound for Door Chime (if
programmed).
z
When the system is in Home arm /
Day Home arm / Night Home arm
mode, if an
Away Entry
Door Contact
is triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if an
Away Entry
Door Contact
is triggered, the Control Panel will not
respond.
)
H for
24H
Burglar Door Contact
z
The
24H burglar
Door Contact is
active at all times and does not have
to be armed or disarmed. An event
code of
133
will be reported.
)
F for
Fire
Door Contact
z
The
Fire
Door Contact is active at all
times and does not have to be armed
or disarmed. An event code of
110
will
be reported.
)
M for
Medical
Door Contact
z
The
Medical
Door Contact is active at
all times and does not have to be
armed or disarmed. An event code of
100
will be reported.
)
W for
Water
Door Contact
z
The
Water
Door Contact acts as an
universal transmitter, and a wired
water leakage sensor can be
connected to it.
z
The
Water
Door Contact is active at
all times and will not have to be armed
or disarmed. An event code of
154
will
be reported.
)
S for
Set/Unset
Door Contact
z
If the Door Contact is set to
Set/Unset
with option selected as
NC
(normal
close), when the Door Contact is
disengaged, the system will enter Arm
mode; when the Door Contact is
engaged, the sytstem will enter Alarm
off mode.
z
If the Door Contact is set to
Set/Unset
with option selected as
NO
(normal
open), when the Door Contact is
engaged, the system will enter Arm
mode; when the Door Contact is
disengaged, the sytstem will enter
Alarm off mode.
<
<
N
N
O
O
T
T
E
E
>
>
)
When the attribute is selected as
Set/Unset, Latch Select must set as
Select
(please refer to section 2.5.4
for details) so that a Latch Report
On/Off selection will appear.
)
NH for
N-Home
Door Contact
z
When the system is in Away arm /
Home arm / Day Home arm mode, if
an
N-Home
Door Contact is triggered,
the Control Panel will start an entry
period to give enough time to disarm
the system.
z
After the delay period is expired and
no correct PIN code is entered to
disarm the system, the Control Panel
will respond with a
Burglar Alarm
after 30 secs and an event code
130
will be reported.