57
4.16.4. Fault Event Response
z
When a fault condition is detected, in
addition to the fault display, the Control
Panel will also respond separately
according to the nature of the fault event.
AC Power Fail / Restore
When the AC power fails, the yellow
LED will light, the fault message
will be displayed, and the system
will send an AC Power Fail report
(code
1301
) to the Central
Monitoring Station in 1 hour.
Whenever Tel+account number or
IP+account number settings exist,
and power is restored from
complete power interruption (either
restored by AC or battery), the
system will send an AC Power
Restore report (code
3301
) to the
Central Monitoring Station in 1 hour.
Control Panel Low Battery
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
If the battery switch is put on OFF
position, the Control Panel will not
detect battery condition.
Any time the Panel battery Low is
detected, the Control Panel will
report,
Low battery
(code
1302
) to
the Central Station in 2 minutes.
However, when the battery is
restored, an
L.B. Restore
(code
3302
) will be reported in 24 hours.
When the AC power works normally,
but the Low Battery Report is sent,
the battery may be faulty.
Control Panel Battery Missing
The Control Panel can detect the
absence of battery in the following
cases:
z
Battery is not connected
z
Battery failure
When any of above condition
happens, the Control Panel will
report
Battery Missing
(code
1311
)
to the Central Station in 24 hours.
When Battery is restored, the
Control Panel will report
Battery
Missing
Restore
(code
3311
) to
the Central Station in 24 hours.
Panel Sabotaged
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
Please refer to 3.3.13. Tamper alarm
under section General Setting to set
the tamper alarm reporting method.
If
Away Arm Only
is selected under
Tamper alarm function, when the
Tamper switch on the Control Panel
is triggered while the system is in
Armed mode, the Control Panel will
emit an audible alarm and report
Panel Tamper
(code
137
) to the
Central Station.
While the system is in Alarm off
mode or Home mode, no report nor
alarm will be generated.
If
Normal
is selected under Tamper
alarm function, when the Tamper
switch on the Control Panel is
triggered, the Control Panel will
emit an audible alarm and report
Panel Tamper
(code
137
) to the
Central Station.
Sensor Low Battery
Any time battery low on any sensor
is detected, the Control Panel will
report
Low battery
(code
384
) to
the Central Station.
Sensor battery restoration is also
reported.
Sensor Sabotaged
If the Tamper switch on the PIR
Sensor, Door Contact, Remote
Keypad, Bell Box (BX-15), is
triggered while the system is in Arm
mode, the Control Panel will emit
an audible alarm and report
Burglar Alarm
(code 130) &
Sensor Tamper Open
(code
383
)
to the Central Station.
While if the system is in Alarm off
mode or Home mode, no reporting
or alarm will be generated.
The Control Panel will report when
the Tamper switch on the sensor is
restored.