17
2.3.3.5 A. Entry Sound (Away Entry
Sound)
This is for you to decide whether the Control
Panel sounds count-down beeps and volume
of beep during the Away entry timer (see
section 2.3.3.1).
z
Options available are
High
(high volume of
beep),
Low
(low volume of beep) and
Off
(no beep):
H i g h
o L o w
O f f
z
Low
is set as factory default.
2.3.3.6 A. Exit Sound (Away Exit Sound)
This is for you to decide whether the Control
Panel sounds count-down beeps and volume
of beep during the Away exit timer (see section
2.3.3.2).
z
Options available are
High
(high volume of
beep),
Low
(low volume of beep) and
Off
(no beep):
z
Low
is set as factory default.
2.3.3.7 H. Entry Sound (Home / Day
Home / Night Home Entry Sound)
This is for you to decide whether the Control
Panel sounds count-down beeps and volume
of beep during the Home entry timer (see
section 2.3.3.3).
z
Options available are
High
(high volume of
beep),
Low
(low volume of beep) and
Off
(no beep):
z
Low
is set as factory default.
2.3.3.8 H. Exit Sound (Home / Day Home
/ Night Home Exit Sound)
This is for you to decide whether the Control
Panel sounds count-down beeps and volume
of beep during the Home exit timer (see
section 2.3.3.4).
z
Options available are
High
(high volume of
beep),
Low
(low volume of beep) and
Off
(no beep):
z
Low
is set as factory default.
2.3.3.9 Door Chime
This function is available only when the
attribute of Door Contact
(DC)
and/or PIR
detector
(IR)
is set as
Entry or Away Entry
.
The Control Panel sounds a Door Chime
(Ding-Dong Sound) while the DC and/or IR is
activated in Alarm off mode.
z
Options available are
High
(high volume of
sound),
Low
(low volume of sound) and
Off
(no sound):
H i g h
L o w
o O f f
z
Area1 Off / Area2 Low
is set as factory
default.
2.3.3.10 Warning Beep
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
This feature is only available for Area 1.
Changes made in Area 1 apply to both
Areas 1 & 2.
This is for you to decide whether the Control
Panel will sound a warning beep every 30 secs
whenever a fault condition has been detected
and displayed. The warning beep will be
silenced after the Fault message has been
read by the user. When a new fault condition is
detected, it will then again emit a warning beep
every 30 sec.
z
Options available are
High
(high volume of
warning beep),
Low
(low volume of
warning beep) and
Off
(no beep):
H i g h
L o w
o O f f
z
Off
is set as factory default.