28
)
When set as Entry, when the Control
Panel is in Alarm Off mode, entering
PIN code followed by pressing the
KP’s Disarm button, the Control Panel
will emit 2 beeps.
)
When set as Entry, when the Control
Panel is in Alarm Off mode, entering
PIN code followed by pressing the
KP’s Arm or Home Arm button, the
Control Panel will enter Away or Home
Arm mode.
B. KP-18
Step 1.
Put the Control Panel into
/-
menu and select the
Add Devices
sub menu. The screen on Control
Panel will show:
À
P u s h b u t
t o n o n
À
De v i c e t o a d d
Step 2.
Apply the AC Power for KP-18. The
KP-18 LCD display will show:
P r e s s “
À
” k e y
f o
r l e a r n
i n g !
<
<
N
N
O
O
T
T
E
E
>
>
)
If the KP-18 unit has been learnt into
any other Control Panel before, KP-18
LCD display will show ”
connecting…
”
after the power is applied. If you would
like to re-learn KP-18, press & hold
the
#
key on KP-18 for 2 sec. You are
required to enter KP PIN Code
(default: 0000) to enter KP Test Mode.
After entering the test mode, please
follow steps 4-6 to relearn KP- LY.
Step 3.
Press & hold the
À
Key on KP-18 for 2
sec to enter KP Test Mode.
Step 4.
Select
Learning
and press
OK
key.
KP-18 LCD will show:
w a i t l e a r n i n g
C o n f i r m . . .
Step 5.
Once the control panel receives the
learning signal, an acknowledgment,
“
Completed
”, will be displayed on KP-
18 with 2 beeps.
Step 6.
At the same time, the screen on
Control Panel will show:
D e t e c t e d : ( O K ? )
K P - 1 8
<
<
N
N
O
O
T
T
E
E
>
>
)
If KP-18 did not receive the
acknowledgement signal, a prompt
message “
No response!
” will be
displayed on KP-18 LCD for 2 sec.
KP-18 will then return to test mode.
Please repeat steps 4-6 to try again.
Step 7.
Press
OK
key on the Control Panel to
confirm. Another prompt message will
be displayed for selecting its zone
number.
Step 8.
Press
OK
key to confirm the zone
number and learning process.
Bell Box (BX-15)
Step 1.
Loose the security screw of BX-15
and open the top case.
Step 2.
Use a sharp object to slide DIP SW3 &
SW4 on BX-15 function switch block to
program your desired alarm period (see
operation manual of BX-15).
Step 3.
Put the Control Panel into
/-
menu and select the
Add Devices
sub menu. The screen on Control
Panel will show:
À
P u s h b
u
t
t o n o n
À
De v i c e t o
a d d
Step 4.
Slide SW1 on BX-15 function switch
block to ON position. BX-15 LED 1 & 3
will flash once with a short beep. BX-
15 is now in learning mode.
Step 5.
Press BX-15 Tamper Switch once to
transmit learning code. BX-15 LED
1&2&3 lights on and BX-15 will start a
15-sec waiting period for receiving the
acknowledgement from the Control
Panel.
Step6.
If the Control Panel receives the
learning signal, the screen displays:
D e t e c t e d : ( O K ? )
B X 1 5
Press
OK
key to confirm. The screen
displays:
S i n g l e a r e a
Wh o l e s y s t e m
Содержание CTC-1241GT