25
z
When the system is in Night Home
arm mode, if
N-Home
Door Contact is
triggered, a
Burglar Alarm
will be
activated immediately. An event Code
of
130
will be reported.
z
When the system is in Alarm off mode,
if an
N-Home
Door Contact is
triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if a
N-Home
Door Contact is
triggered, the Control Panel will not
respond.
)
SP for
24H-Special
Door Contact
z
The
24H-Special
Door Contact is
active at all times and does not have
to be armed or disarmed. When a
24H-Special
Door Contact is triggered
(both open and close), the Control
Panel will report a secret alarm
message (both open and close)
without sounding the siren to the
Central Monitoring Station and
sending a SMS message to the
mobile phone number (if programmed).
An event code of
1150
for Open, and
3150
for Close will be reported.
StepA7.
Use
S
&
T
keys to make your
selection and confirm by pressing
OK
key.
StepA8.
The zone name & device attribute is
displayed. Press
OK
key again to
confirm.
I n s t a l l e d : ( O K ? )
D C B a c k d o o r B
StepA9.
You are now invited to give a name
or location description to the device
to help understand system events.
You can enter up to 10 characters
followed by
OK
key or just press
OK
key for no name. Please see
Appendix I
Naming
for more details.
E
d
i t n
a m e
. . . . . . . . . . . .
Adding a Door Contact is now
complete.
<
<
N
N
O
O
T
T
E
E
>
>
)
If
key is pressed during the Edit
Name step, the Door Contact will use
zone number to display instead of a
name.
If the attibute selected is Set/Unset, please
continue the below steps:
Step A10.
Press
OK
key to confirm preferred
Device attribtue. Choose whether
you wish to enable or disable the
Latch option and press
OK
key.
o L a t c h . R p t . O n
L a t c h . R p t . O f f
<
<
N
N
O
O
T
T
E
E
>
>
)
For description of latch report option,
please refer to section 2.3.1.1 PIN
Code setting, Step 5.
Step A11.
Select
NO
(normal open)
or
NC
(normal close) and press
OK
key to
confirm.
o N O
N C v
PIR Detector
StepB7.
After a zone number for the PIR is
assigned, the device attribute will be
displayed for selection:
o B u r g l a r
H o m e O m i t
D . H o m e O
m i t
N . H o m e O
m i t
H o m e A c c e s s
D e l a y Z
o
n
e
A w a y O n l y
E n t r y
A w a y E n t r y
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
For detailed description of PIR
Detector in each device attributes,
please refer to Step A7 for adding
Door Contact.
Содержание CTC-1241GT
Страница 1: ...f 25 MAR 2010 For THIRKILD DENMARK...