62
ITEM
COMMAND USAGE
DESCRIPTION
APNSR
PROG 7982
APNSR:
INTERNET
Enter the APN Server detail (provided by your telecom supplier)
(Max.30 digitals)
PROG 7982
TCIP1:A1
192.168.1.234
Enter the IP Address (provided by your CMS supplier)
A1
192.168.1.234
Æ
A = First Priority; 1=IP Address
TCIP1
PROG 7982
TCIP1:B1
192.168.1.234
Enter the IP Address (provided by your CMS supplier)
B1
192.168.1.234
Æ
B = Second Priority; 1=IP Address
TCIP2
PROG 7982 TCIP2:
2
WWW.CLIMAX.COM.TW
Enter the URL (provided by your CMS supplier)
2
WWW.CLIMAX.COM.TW
Æ
2=URL (Reserved)
PORT1
PROG 7982 PORT1:
50000
Enter the Port detail (provided by your CMS supplier)
(Max.5 digitals)
PORT2
PROG 7982 PORT2:
53011
Enter the Port detail (provided by your CMS supplier)
(Max.5 digitals)
IPAC1
PROG 7982 IPAC1:
1241
Enter the 4 or 6 digits for the first IP account number
IP.Setting
(see Note 3)
IPAC2
PROG 7982 IPAC2:
1241
Enter the 4 or 6 digits for the second IP account number
PROG 7982 SDELA:
100
100
Æ
1(Area 1) 00 (siren
delay time is 0 min),
Siren Delay
SDELA
PROG 7982 SDELA:
210
210
Æ
2(Area 2) 10 ( siren
delay time is 10 mins)
To set siren delay time (0~10 mins)
for 00 for 0 Min, …, and 10 for 10
mins
PROG 7982 VERIF:
10/20
To set verification option function:
10
Æ
1 (Area 1) 0 (function disable)
20
Æ
2 (Area 2) 0 (function disable)
Verification VERIF
PROG 7982 VERIF:
11/21
11
Æ
1 (Area 1) 1 (function enable)
21
Æ
2 (Area 2) 1 (function enable)
PROG 7982 FNLDR:
10/20
To set final door option function:
10
Æ
1 (Area 1) 0 (function disable)
20
Æ
2 (Area 2) 0 (function disable)
Final Door
FNLDR
PROG 7982 FNLDR:
11/21
11
Æ
1 (Area 1) 1 (function enable)
21
Æ
2 (Area 2) 1 (function enable)
PROG 7982 JAMMG:
0
Interference JAMMG
PROG 7982 JAMMG:
1
To set interference option function (for both Areas);
0
Æ
function disable
1
Æ
function enable
PROG 7982 CHKIN:
00
To set auto check-in reporting function (for both Areas);
00
Æ
function disable
PROG 7982 CHKIN:
01
01
Æ
Auto-Check In reporting for every 15mins
02
Æ
Auto-Check In reporting for every 30mins
PROG 7982 CHKIN:
02
03
Æ
Auto-Check In reporting for every 1 hour
04
Æ
every 2 hours; 05
Æ
every 3 hours; 06
Æ
every 4 hours
07
Æ
every 6 hours; 08
Æ
every 8 hours; 09
Æ
every 12 hours
PROG 7982 CHKIN:
09
10
Æ
Auto-Check In reporting for everyday
PROG 7982 CHKIN:
10
11
Æ
Auto-Check In reporting for 2 days
12
Æ
every 3 days; 13
Æ
every 4 days; 14
Æ
every 5 days;
15
Æ
every 6 days
PROG 7982 CHKIN:
15
16
Æ
Auto-Check In reporting for weekly
17
Æ
every 2 weeks; 18
Æ
every 3 weeks
Check-in Rpt
CHKIN
PROG 7982 CHKIN:
18
19
Æ
Auto-Check In reporting for every 4 Weeks
PROG 7982 OFFST:
01
To set offset period (for both Areas):
01
Æ
auto check-in reporting will be send after the first hour
PROG 7982 OFFST:
02
02
Æ
auto check in reporting will be send after 2 hours
PROG 7982 OFFST:
03
03
Æ
auto check in reporting will be send after 3 hours
PROG 7982 OFFST:
08
08
Æ
auto check in reporting will be send after 8 hours
PROG 7982 OFFST:
10
10
Æ
auto check in reporting will be send after 10 hours
Offset Period
OFFST
PROG 7982 OFFST:
12
12
Æ
auto check in reporting will be send after 12 hours
Содержание CTC-1241GT
Страница 1: ...f 25 MAR 2010 For THIRKILD DENMARK...