27
)
F for
Fire
Remote Controller
Control Panel will give a
Fire
alarm
when the panic button is pressed &
held for 3 seconds or pressed twice
within 3 seconds. An event code of
110
will be reported.
)
AUX for
AUX
Remote Controller
z
When Output is set as N.O. (please
refer to section
2.4.2. Output Config
),
and when the panic button is pressed
& held for 3 seconds or pressed twice
within 3 seconds. Output will switch to
N.C. for 1 second, then switch back to
N.O.
z
When Output is set as N.C. (please
refer to section
2.4.2. Output Config
),
and when the panic button is pressed
& held for 3 seconds or pressed twice
within 3 seconds. Output will switch to
N.O. for 1 second, then switch back to
N.C.
<
<
N
N
O
O
T
T
E
E
>
>
)
Remote Controller triggered AUX will
not raise an alarm, nor will it be
reported or logged.
StepD8.
Press
OK
key to confirm preferred
Device attribtue. Choose whether
you wish to enable or disable the
Latch option and press
OK
key.
* L a t c h . R p t . O f f
L a t c h . R p t . O n
<
<
N
N
O
O
T
T
E
E
>
>
)
For description of latch report option,
please refer to section 2.3.1.1 PIN
Code setting, Step 5.
StepD9.
You are then requested to choose
whether or not the system can be
armed / disarmed via Remote
Controller, followed by an
OK
.
o
R
C
E
N
T
E
O
n
R
C
E
N
T
E
O
f f
<
<
N
N
O
O
T
T
E
E
>
>
)
For description of Remote Controller
Entry Enable option, please refer to
section 2.5.7.
StepD10.
Follow the same learning procedure
as described in section 2.3.6.1 Add
Device, steps A8-A9 to confirm
learning & naming the device.
I n s t a l l e d : ( O K ? )
R C M R . S M I T H
Remote Keypad
A. KP-9
Step 1.
Key-in the 4 digit PIN code of KP-9
(0000 is set as factory default)
followed by the
*
key. A long beep
will sound on KP-9 with the active
Green LED turned on.
Step 2.
Put the Control Panel in
Add Device
mode. The following screen will be
displayed:
* P u s h b u t t o n o n *
D e v i c e t o
a d d
Step 3.
Press
*
key followed by numeric
7
on
KP-9 to transmit a learning code. A
long beep will sound on KP-9 if the
transmission is successful.
Step 4.
After Control Panel receives the signal
from KP-9, it will send an
acknowledgement back to KP-9. KP-9
will then beep 3 times to confirm the
acknowledgement has been received.
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
If KP-9 does not perform 3 beeps in
Step 4, please restart the learning
procdeure from Step 1.
Step 5.
Press
OK
to confirm. Another
prompting message will be displayed
for selecting its zone number.
Step 6.
Press
OK
to confirm the zone number.
Step 7.
Select the KP’s attribute and press
OK
to confirm & naming of the device.
À
K P
E n t r y
<
<
N
N
O
O
T
T
E
E
>
>
)
When set as Entry, when the Control
Panel is in Away / Home / Day Home /
Night Home Arm mode, entering PIN
code followed by pressing the KP’s
Disarm button, the Control Panel will
start Entry Timer.
Содержание CTC-1241GT