16
2.3.3.1 A. Entry Timer (Away Entry
Timer)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Away Entry / Home Access
attribute, the system gets into counting down
period (Away entry timer) while the DC or IR is
triggered under Away arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
z
Options available are
Disable
(alarm
immediately) ,
10 sec
,
20 sec
, up to
70
sec
in 10-sec increments.
z
Press
OK
on A. Entry Timer and the
following screen will be displayed:
D
i s a b
l e
1 0 s e c
o
2 0 s e c
3 0 s e c
4 0 s e c
5 0 s e c
6 0 s e c
7 0 s e c
z
20 sec
is set as factory default.
2.3.3.2 A. Exit Timer (Away Exit Timer)
While the system gets into Away arm mode by
Control Panel, Remote Controller (RC) or
Remote Keypad (KP), an Away exit timer starts
counting down.
During the counting down period, pressing the
Arm Button of the RC can restart the counting.
In addition, it is allowed to use correct PIN
code or press Disarm Button of the RC to stop
the counting and return to Alarm off mode.
z
Options available are
Disable
(exit timer
prohibited),
10 sec
,
20 sec
up to
70 sec
in
10-sec increments.
z
30 sec
is set as factory default.
2.3.3.3 H. Entry Timer (Home / Day
Home / Night Home Entry Timer)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Away Entry / Home Access
attribute, the system gets into counting down
period (Home entry timer) while the DC or IR is
triggered under Home / Day home / Night
home arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
z
Options available are
Disable
(alarm
immediately) ,
10 sec
,
20 sec
, up to
70
sec
in 10-sec increments.
z
30 sec
is set as factory default.
2.3.3.4 H. Exit Timer (Home / Day Home /
Night Home Exit Timer)
While the system gets into Home / Day Home /
Night Home arm mode by Control Panel,
Remote Controller (RC) or Remote Keypad
(KP) or Night Switch (NS), an Away exit timer
starts counting down.
During the counting down period, pressing the
Home Button of the RC can restart the
counting. In addition, it is allowed to use
correct PIN code or press Disarm Button of the
RC to stop the counting and return to Alarm off
mode.
z
Options available are
Disable
(exit timer
prohibited),
10 sec
,
20 sec
up to
70 sec
in
10-sec increments.
z
10 sec
is set as factory default.