23
)
O for
Home Omit
Door Contact
z
When the system is in Away Arm
mode (incl. away arm entry), if a
Home Omit
Door Contact is triggered,
a burglar alarm will be activated
immediately. An event Code of
132
will be reported.
z
When the system is in Home Arm /
Day Home Arm / Night Home Arm
mode, if a
Home Omit
Door Contact
is triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if a
Home Omit
Door Contact
is triggered, the Control Panel will not
respond.
)
DO for
Day Home Omit
Door
Contact
z
When the system is in Away arm /
Night Home arm mode, if a
Day
Home Omit
Door Contact is triggered,
a burglar alarm will be activated
immediately. An event Code of
132
will be reported.
z
When the system is in Day Home
mode, if a
Day
Home Omit
Door
Contact is triggered, the Control Panel
will not respond.
z
During the Entry Delay or Exit Delay
period, if a
Day Home Omit
Door
Contact is triggered, the Control Panel
will not respond.
)
NO for
Night Home Omit
Door
Contact
z
When the system is in Away arm / Day
Home arm mode, if a
Night Home
Omit
Door Contact is triggered, a
burglar alarm will be activated
immediately. An event Code of
132
will be reported.
z
When the system is in Night Home
mode, if a
Night
Home Omit
Door
Contact is triggered, the Control Panel
will not respond.
z
During the Entry Delay or Exit Delay
period, if a
Night Home Omit
Door
Contact is triggered, the Control Panel
will not respond.
)
A for
Home Access
Door Contact
z
When the system is in Away arm
mode, if
Home Access
Door Contact
is triggered, a burglar alarm will be
activated immediately. An event Code
of
130
will be reported.
z
When the system is in Home arm /
Day Home arm / Night Home arm
mode, if a
Home Access
Door
Contact is triggered, the Control Panel
will start an Entry Delay period to give
enough time to disarm the system.
z
During the Entry Delay or Exit Delay
period, if a
Home Access
Door
Contact is triggered, the Control Panel
will not respond.
)
D for
Delay Zone
Door Contact
z
When the system is in Away arm /
Home arm / Day Home arm / Night
Home arm mode, if a
Delay Zone
Door Contact is triggered, a burglar
alarm will be activated immediately.
An event Code of
130
will be reported.
z
During the Entry Delay or Exit Delay
period, if a
Delay Zone
Door Contact
is triggered, the Control Panel will not
respond.
)
Y for
Away Only
Door Contact
z
When the system is in Away arm
mode, if an
Away Only
Door Contact
is triggered, a burglar alarm will be
activated immediately. An event Code
of
130
will be reported.
z
When the system is in Home arm /
Day Home arm / Night Home arm
mode, if an
Away Only
Door Contact
is triggered, the Control Panel will not
respond.
z
During the Entry Delay or Exit Delay
period, if an
Away Only
Door Contact
is triggered, the Control Panel will not
respond.
)
E for
Entry
Door Contact
z
When the system is in Away arm /
Home arm / Day Home arm / Night
Home arm mode, if an
Entry
Door
Contact is triggered, the Control Panel
will start an entry period to give
enough time to disarm the system.
Содержание CTC-1241GT