67
5.4.6. Message Composition
The form of the message is:
Where
ACCT MT QXYZ GG C
1
C
2
C
3
ACCT
= 4 Digit Account number (0-9, B-F)
MT
= Message Type, 18H.
Q
= Event qualifier, which gives specific
event information:
XYZ
= Event code (3 Hex digits 0-9, B-F)
GG =
Area number
(00=Area 1, 01=Area 2)
C
1
C
2
C
3
= 1. For devices: zone number
C
1
C
2
C
3
= Zone number
001 Zone 1
002 Zone 2
…………………..
080 Zone 80
2. For Panel: code
C
1
C
2
C
3
= Code
Guardian code Tel 1
939
Guardian code Tel 2
940
Guardian code IP 1
931
Guardian code IP 2
932
User PIN Code 1
001
User PIN Code 2
002
User PIN Code 3
003
User PIN Code 4
004
User PIN Code 5
005
User PIN Code 6
006
Web 961
Temporary Code
901
Duress Code
929
Control Panel
000
Control Panel Input Terminal
081
5.4.7. Data Tone
The message is sent using standard DTMF
tones.
The timing of the tones shall be as follows:
Burst ON time – 50 msec. (50 min., 60 max.)
Burst OFF time – 50 msec. (50 min., 60 max.)
5.4.8. Kiss off (Acknowledgement)
Tone
The Kiss off tone from the receiver is used to
tell the Control Panel that the message has
been received successfully. The frequency of
the tone is 1400 Hz. ± 3%. The Control Panel
detects a minimum of 400 msec. of tone before
considering the kiss off to be valid.
5.4.9. Event Code
5.4.9.1. Medical Alarms
z
100 - Medical
When the Wrist Transmitter (WTR, RC,
DC or Panel) is triggered.
z
101 - Personal Emergency
When the Wrist Transmitter (WTR) or
Emergency Pendant is pressed.
5.4.9.2. Fire Alarms
z
110 - Fire
When the DC, Panel, RC is triggered.
z
111 - Smoke
When the Smoke Detector (SD) is
triggered.
5.4.9.3. Panic Alarms
z
120 - Panic
When the Panic Button of the Remote
Controller (RC or WTR) is pressed.
z
121 - Duress
When the Duress Code is entered to
Disarm or Arm the system.
z
122 - Silent Panic
When the Panic Button of the Remote
Controller
、
WTR is pressed.
Содержание CTC-1241GT