2.3.6.1 Add Devices
Step 1.
Select
Add Device
, then press
OK
, a
prompting message is displayed.
* P u s h B u t t o n O n *
D e v i c e t o a d d
Step 2.
Press the learn/test button on the
sensor or any button on the Remote
Controller.
Step 3.
If the learning code is received
successfully by the Control Panel, the
screen will show you the device type.
D e t e c t e d ( O k ? )
D o o r C o n t a c t
<
<
N
N
O
O
T
T
E
E
>
>
)
Aavailable devices are listed as follow:
9
Door Contact --- DC
9
PIR Sensor --- IR
9
Pet Immune PIR Sensor--IRP
9
Remote Controller --- RC
9
Carbon Monoxide --- CO
9
Smoke Detector --- SD
9
Water Sensor --- WS
9
Panic Button --- PB
9
Night Switch --- NS
9
Tag Reader --- TG
9
Two-way Radio Keypad ---
KP-9, KP-18 (with LCD)
9
Siren --- BX-15, SR-15
Step 4.
Press
OK
to continue the learning
process. Another prompting message
will be displayed for you to select its
zone number.
Step 5.
All non-occupied zones (zones which
have no device added in yet) will be
displayed on the screen for selection.
Step 6.
Use
S
&
T
keys to move the cursor to
the desired zone number then press
OK
.
<
<
N
N
O
O
T
T
E
E
>
>
)
When a sensor is added to the system
for the second time (without removing
it first). An error message will be
displayed for 2 sec.
A l r e a d
y E
x i s t
i n s y s t e m
The screen will return to Step 1
automatically for you to add a new
device.
)
Pressing
key will abort the
procedure and will not learn-in the
device.
)
Different screens will be displayed for
different device types for further
configuration purpose.
Door Contact
StepA7.
After a zone number for the Door
Contact is assigned, you can further
specify the device attribute for how it
will work in different situations.
z
Device
Attribute:
B u r g l a r
H o m e O m i t
D . H o m e O m i t
N . H o m e O m i t
H o m e A c c e s s
D e l a y Z o n e
A w a y O n l y
E n t r y
A w a y E n t r y
2 4 H B
u
r g
l a r
F i r e
M e d i c a l
Wa t e r
S e t \ U
n
s e t
N - H o m e
2 4 H - S
<
<
N
N
O
O
T
T
E
E
>
>
)
B for
Burglar
Door Contact
z
When the system is in Away Arm /
Home Arm / Day Home Arm / Night
Home Arm mode, or during the Entry
Delay or Exit Delay period, if a
Burglar
Door Contact is triggered, a
Burglar Alarm will be activated
immediately, an event Code
130
will
be reported.