2.5.3. Supervision
This option is used to enable system
supervision function. When
ON
is selected,
CTC-1241 will be able to receive the check-in
signals from the devices to indicate their proper
functioning.
D
i s a b
l e
4 H o u r s
6 H o u r s
8 H o u r s
1 2 H
o
u
r s
2 4 H
o
u
r s
PIR sensor, Door Contact, Water Sensor or
Smoke Sensor, after installed, will transmit a
periodic supervision signal at intervals between
30 min. to 50 min.
If the Control Panel dose not receive the
signals transmitted from an individual sensor
for a period of 4 Hours, 8 Hours, 12 Hours, a
sensor out-of-order
fault event will be
detected.
z
12 Hours
is set as factory default.
2.5.4. Latch Select
Latch report
is sent while system mode is
changed (e.g. from Away arm mode to Alarm
off mode) and can be applied to control prompt
situation from the system.
This function is to program whether Control
Panel send latch key report while the system
mode is changed.
o L a t c h
S
e
l e
c t
L a t c h
O
f f
L a t c h O n
z
Latch On
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
When the Latchkey reporting feature
is
Latch
Select
, the system will ask
your option for latch report while you
program PIN & Temporary codes and
while you learn Remote Controller in
the Control Panel.
)
When the Latchkey reporting feature
is
OFF
, the system does not inform all
arming and disarming actions of all
users and the RC to Central
Monitoring Station or users.
)
When the Latchkey reporting feature
is
ON
, the system informs all arming
and disarming actions of all users and
the RC to Central Monitoring Station
or users.
2.5.5. Area Sound
The Area Sound is used to set the audio pitch
of the beeps for key pressing, entry/exit
counting-down and door chime.
Options available are
High
(high audio pitch)
and
Low
(low audio pitch).
H i g h
o L o w
z
Low
is set as factory default.