19
2.3.3.14 Tamper Alarm
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
This feature is only available for Area 1.
Changes made in Area 1 apply to both
Areas 1 & 2
.
This is for you to choose whether the siren
should sound when a tamper is triggered.
A
w
a y A r m O
n
l y
o N o r m a l V
z
Normal
is set as factory default.
)
Away Arm Only
means, when tamper
is triggered under Away arm mode,
Control Panel raises a local alarm and
sends report to the monitoring center.
While under others modes (Home /
Alarm off modes, etc.), the siren does
not sound nor any report will be sent
(see sections 4.16 & 4.16.4).
)
Normal
means, Control Panel raises
a local alarm
for tamper-trigger and
sends report to the monitoring center
in all modes.
)
Either
Away arm only
or
normal
is
selected, the system sends tamper-
triggered report to Central Monitoring
Station in all modes while tamper is
triggered.
2.3.3.15 AC Report
<
<
I
I
M
M
P
P
O
O
R
R
T
T
A
A
N
N
T
T
N
N
O
O
T
T
E
E
>
>
)
This feature is only available for Area 1.
Changes made in Area 1 apply to both
Areas 1 & 2.
This is for you to decide whether the Control
Panel should report to Central Monitoring
Station when AC failure is detected.
o R e p o r t o n
R
e p
o
r t o
f f v
z
Report On
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
)
When
Report on
is selected, the
control unit will report an AC failure
Contact ID code to Central Monitoring
Station if AC fault resides for more
than 50 mins. The reporting will be
made within 10 mins after reaching
the 50-min threshold.
)
When
Report off
is selected, the
control unit will not report any AC
failure.
)
Once AC power is restored, an AC
restored Contact ID code will be
reported to the Central Monitoring
Station within 5 mins.
2.3.3.16 Alarm Length
This is for you to select the built-in siren
duration when an alarm is activated. Options
are
Disable
(no siren alarm) and
1 Min
to
15
Min
in 1-Min increments.
D i s a b l e
1 M i n
2 M i n
o 3 M i n
4 M i n
5 M i n
to
1 5 M i n
z
3 Min
is set as factory default.
z
If
Disable
is selected, when the Control
Panel receives an alarm signal, the panel
siren and internal & external sirens (SR &
BX) will not raise an alarm sound.
z
If 1-15 min is selected and the local siren
function is disabled (see section 2.3.3.12
above), the panel siren will not raise an
alarm sound when alarm is triggered.
However, the BX will raise siren based on
your programming (see the operation
manual of BX).
z
If BX’s alarm length is longer than the
Control Panel’s, the system gives priority
to the Control Panel. (e.g. when the BX’s
alarm length is set as 3 mins, and the
panel’s alarm length is set as 1 min, both
alarm siren stop at 1 min when alarm is
triggered; however, the BX’s LED keeps
flashing until 3 mins is expired.