background image

 

              

48

4.8.2. Arming the System via 

Remote Controller 

Step 1. 

Press once on Full Arm or Home Arm 
button.  

Step 2.

  Repeat steps 2-6 as described in 

Arming the system via Control 
Panel

.  

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

For Exit Delay performance, please 
refer to <IMPORTANT NOTE> on Exit 
Delay Count Down Period under 
section 4.2. Away Arm Mode. 

)

 

The 

Fault Display

 screen has a time-

out of 2 minutes

 

and will then 

automatically return to

 Alarm Off

 

screen if no 

OK

  of  Arming  is 

confirmed. 

)

 

If a sensor is bypassed (please see 

section 4.7. Bypass

), the fault 

condition of that sensor will not be 
checked.

  

 

 

)

 

If a sensor is tampered or out-of-order, 
you can temporarily bypass it or 
permanently remove it.  

)

 

Force arming record can be checked 
in the 

Log

 section. 

 

4.8.3. Arming with Door Opened 

z

  While arming the system, if any Door 

Contact is detected as Open, the Control 
Panel will emit a ding-dong sound to 
indicate arming is prohibited.  

 

z

 If user manually shuts the Door 

immediately, the fault display will then be 
automatically cleared and the screen 
returns to

 Alarm off

.  You can then arm 

the system again. 

z

  However, if you wish to put the system 

into Arm mode with the door open, follow 
the steps as described in

 Section 4.8. 

Force Arming

 

 

 

 

4.8.4. Arming with IR Triggered  

z

  While arming the system, if any PIR 

Motion Detector is activated, the Control 
Panel will prohibit the Arming within 5 sec 
of its activation.

 

z

  The user can only arm the system when 

the IR is not activated.  

 

4.8.5. Arming with Supervisory 

Fault  

z

  The PIR sensor, Door Contact, Water 

Sensor or Smoke Sensor, after installed, 
will transmit a periodic supervision signal 
at intervals between every 30 to 50 min. 

z

  When arming the system, if the Control 

Panel has not received the Supervisory 
Signal transmitted from any individual 
sensor over a pre-setting period, a fault 
event, 

Lost of signal w/ sensor zone & 

name

, will be displayed on the screen.  

z

  However, if you want to put the system 

into Arm mode with the supervisory fault, 
follow the Steps described in

 Section 4.8 

Force Arming 

for operation. 

 

4.9. Alarm Off Mode 

If the system is in either the Away Arm mode or 
Home Arm mode (Alarm ON), enter your pin 
Code and press

 OK

. If the PIN code is correct, 

the Control Panel will sound 2 short beeps and 
return to Alarm off mode. The display will show 
both screens at every second flash. 

 

 A l a r m  O 

f f      

  0 0 : 0 1    0  1    J  a n    

 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

When the system is Home Armed, 
Day Home Armed or Night Home 
Armed, pressing the

 DISARM

 button 

on the Remote Controller will disarm 
the system.

 

)

 

When the system is Away Armed, 
pressing the 

DISARM 

button on the 

Remote Controller can disarm the 
sytem when either an 

Entry

 device 

has been triggered, or when the 

Remote Controller Entry Enable

 has 

been set to 

ON

Содержание CTC-1241GT

Страница 1: ...f 25 MAR 2010 For THIRKILD DENMARK...

Страница 2: ...______________________________ 12 2 3 Area __________________________________________________________________________ 13 2 3 1 Code Settings ___________________________________________________________...

Страница 3: ...________________________________________________ 44 4 4 Day Home Arm ________________________________________________________________ 44 4 5 Night Home Arm ____________________________________________...

Страница 4: ...Display_____________________________________________________________ 56 4 16 2 Clearing Fault Message Display ____________________________________________________ 56 4 16 3 Viewing Clearing the Fault...

Страница 5: ...r and scroll the display downwards Backlit Key In Programming mode use this key for deleting a digit canceling the selection aborting the current screen and returning to the previous screen Backlit OK...

Страница 6: ...rt to the Monitoring Station z To Insert your SIM card N NO OT TE E It is recommended to disable the SIM card PIN code before inserting into the Control Panel The GSM SIM card base is situated inside...

Страница 7: ...ly charge the battery z Battery Switch is set as ON by factory default If switched to OFF the battery will not be charged when AC power is connected nor will it serve as a back up power source when AC...

Страница 8: ...any combination within the two areas as long as they add up to 50 E g 8 PIN in Area 1 42 in Area 2 or 30 in Area 1 20 in Area 2 z When an identical PIN code is in both Areas 1 2 then that PIN code be...

Страница 9: ...nt date time will be displayed During entering PIN code if incorrect codes have been inputed for 4 times or over 20 incorrect numeric numbers have been entered it will inhibit further key presses for...

Страница 10: ...mode To change and save any settings enter the programming menu in Alarm off mode only If not in Alarm off mode or if AC power battery are both off then the changes will not be saved Regardless if an...

Страница 11: ...Change Tel Numbers Apply Steps 1 5 from Store Tel Numbers section on the number that is wished to change New numbers will overwrite the previous one z Delete Tel Numbers Step 1 Apply Steps 1 2 from St...

Страница 12: ...e guardian code function will be disabled automatically 2 1 2 IP Settings o C e n t r a l I P P o r t A d d r e s s A c c n u mb e r A P N G P R S v U s e r n a me G P R S P a s s w o r d G P R S 2 1...

Страница 13: ...the Central Monitoring Station IP Address that has been programmed After the Central Monitoring Station s IP address is set its corresponded 4 or 6 digit account number will need to be entered N NO O...

Страница 14: ...E d i t o r _ Step 1 Please enter your Password max 15 digits alphabets and press OK key Step 2 Select Save to save the data or select Quit to give up saving 2 1 3 SMS Numbers In an alarm event panel...

Страница 15: ...will not report to any second priority IP Address nor phone number unless all First Priority IP address phone number failed 2 Back up 1 Rather than only report the First Priority IP addresses phone n...

Страница 16: ...atter what the method of contact is all First Priorities will be carried out before the system moves onto Second Priorities Within the same level of priority IP address still has a higher priority tha...

Страница 17: ...ode cannot be the same within the same area but can be the same in the other area If the code has been used the screen will display code in use and require you re enter a new code 2 3 1 1 PIN Code I I...

Страница 18: ...4 PIN code is not yet set up for activation Step 9 Proceed to set additional User PIN Codes as instructed from Steps 1 8 I IM MP PO OR RT TA AN NT T N NO OT TE E To name the User Names please refer to...

Страница 19: ...r a temporary user The temporary Code is ONLY valid for one access per arming and disarming Afterwards the Temporary Code will be automatically erased and needs to be reset for a new Temporary user z...

Страница 20: ...ns available are Disable exit timer prohibited 10 sec 20 sec up to 70 sec in 10 sec increments z 30 sec is set as factory default 2 3 3 3 H Entry Timer Home Day Home Night Home Entry Timer When Door C...

Страница 21: ...sounds count down beeps and volume of beep during the Home exit timer see section 2 3 3 4 z Options available are High high volume of beep Low low volume of beep and Off no beep z Low is set as factor...

Страница 22: ...d Water is triggered or whenever any keys of the Control Panel RC KP is pressed within the pre set Mobility time period The mobility function is disabled automatically when the system is set to Away A...

Страница 23: ...ort on is selected the control unit will report an AC failure Contact ID code to Central Monitoring Station if AC fault resides for more than 50 mins The reporting will be made within 10 mins after re...

Страница 24: ...ntact set as Entry device the system will automatically full arm once the Door Contact is detected as closed even if the count down period is not yet complete o F i n a l d o o r O n F i n a l d o o r...

Страница 25: ...header N NO OT TE E When Save is chosen the saved SMS header will be sent along with the SMS status message to mobile phone If no SMS header is programmed only the SMS alarm message will be send to m...

Страница 26: ...e the cursor to the desired zone number then press OK N NO OT TE E When a sensor is added to the system for the second time without removing it first An error message will be displayed for 2 sec A l r...

Страница 27: ...ol Panel will not respond A for Home Access Door Contact z When the system is in Away arm mode if Home Access Door Contact is triggered a burglar alarm will be activated immediately An event Code of 1...

Страница 28: ...t z The Fire Door Contact is active at all times and does not have to be armed or disarmed An event code of 110 will be reported M for Medical Door Contact z The Medical Door Contact is active at all...

Страница 29: ...now invited to give a name or location description to the device to help understand system events You can enter up to 10 characters followed by OK key or just press OK key for no name Please see Appen...

Страница 30: ...ght Home Arm mode the Control Panel will emit a warning beep every 2 sec until the pre defined Alarm Length expires The LCD display remains unchanged No reporting will be made When EIR is triggered in...

Страница 31: ...n of Remote Controller Entry Enable option please refer to section 2 5 7 StepD10 Follow the same learning procedure as described in section 2 3 6 1 Add Device steps A8 A9 to confirm learning naming th...

Страница 32: ...ed will be displayed on KP 18 with 2 beeps Step 6 At the same time the screen on Control Panel will show D e t e c t e d O K K P 1 8 N NO OT TE E If KP 18 did not receive the acknowledgement signal a...

Страница 33: ...od see operation manual of SR 15 Step 3 Put the Control Panel into Device menu and select the Add Devices submenu The screen on Control Panel shows Push button on Device to add Step 4 Slide DIP SW1 on...

Страница 34: ...ices in the Device menu all the devices being included in the system will be displayed You may Press to exit D C B a c k d o o r I R H a l l w a y R C M R S M I T H S D K i t c h e n S T O P To Edit D...

Страница 35: ...ss key to return to Device menu 2 3 6 3 Remove Devices Adding a device for a second time is prohibited unless it is removed from the system first To delete a device choose Remove Device in the Device...

Страница 36: ...ystem and press OK key the screen displays Pls wait RF transmitting and a learning code is transmitted to BX SR please refer to the operation manual of the devices to finish the further process Step 4...

Страница 37: ...glar When a burglar alarm is triggered PSS will turn on when the system is disarmed PSS will turn off z Set Unset All When Set Unset is selected NC normal close NO normal open options will be displaye...

Страница 38: ...eted press OK key to save the new setting and return to the previous menu z To Remove PSS To remove a PSS from the system simply select the channel and change the attibute to Disable Press OK key to s...

Страница 39: ...l y 2 4 H b u r g l a r F i r e M e d i c a l Wa t e r S e t U n s e t Step 3 Select the desired attribute and press OK Step 4 A NC normal close NO normal open option is required to choose N C o N O V...

Страница 40: ...riod of time between check in reports Options available are Disable 15 Min 30 Min 1 Hr up to 4 Weeks o D i s a b l e 1 5 M i n 3 0 M i n 3 We e k s 4 We e k s z 1Day is set as factory default 2 5 2 Of...

Страница 41: ...tuation from the system This function is to program whether Control Panel send latch key report while the system mode is changed o L a t c h S e l e c t L a t c h O f f L a t c h O n z Latch On is set...

Страница 42: ..._7982_UNAM1 1 where _ means a space 2 5 7 Remote Controller Entry Enable Select RC Ent E This is to Turn On or Off the Remote Controller disarm function R C E n t E O p t R C E n t E O n R C E n t E O...

Страница 43: ...sec Step 4 Press OK The following message is displayed for 2 sec We l c o me t o P r o g r a m me n u Step 5 Then the Programming Main menu will be displayed o A r e a G S M V Step 6 Move the cursor...

Страница 44: ...ary between different Telecom companies Thus you can either check with your Telecom provider or follow the steps described below to check the correct format Step 1 Remove the SIM card from SIM Card ho...

Страница 45: ...0 S e c N NO OT TE E If the screen automatically returns to programming menu this means the reset process is sucessful z After a successful reset the following screen will be displayed and the panel w...

Страница 46: ...e a 1 A r e a 2 A r e a 1 A r e a 2 z When Area1 or Area2 is selected the screen will be the same as shown in 4 1 1 z When Area1 Area2 is selected then screen will show A w a y A r m H o me A r m D a...

Страница 47: ...n Final Door Option is set as Off the Control Panel enters Alarm On mode only when the Exit Delay time is up The system can also be armed by pressing the LOCK symbol the Remote controller Only if the...

Страница 48: ...ssing the HOME symbol on Remote Controller 4 4 Day Home Arm Day Home Arm Mode allows the home to be partially armed during a particular time period such as Day time only It operates similar to Home Ar...

Страница 49: ...Delay count down can not be extended in Night Home mode Step 2 When Exit Delay timer expires the Control Panel will emit 3 beeps and the system is now in Night Home Arm Mode 4 6 Timer o T i me D a t e...

Страница 50: ...1 O c l o c k 2 O c l o c k Step 5 Select the starting hour and press OK o 2 H o u r s 1 H o u r 1 H o u r 2 H o u r s Step 6 Choose the desired hour and press OK z End Month Step 1 Select End Month...

Страница 51: ...ult Event in Fault Display section please see section 4 16 Fault Situations z However if you would like to arm the system while the fault situation persists it is still possible by following the steps...

Страница 52: ...tem if any PIR Motion Detector is activated the Control Panel will prohibit the Arming within 5 sec of its activation z The user can only arm the system when the IR is not activated 4 8 5 Arming with...

Страница 53: ...the Control Panel including 9 All Alarm Events with Device ID 9 All Arming Partial Arming Bypass Arming and Disarming Events z The logged events are displayed in reverse chronological order i e most r...

Страница 54: ...Omit NO No Response Instant Burglar Alarm No Response Instant Burglar Alarm No Response No Response Instant Burglar Alarm No Response Home Access A No Response Instant Burglar Alarm Start Entry Timer...

Страница 55: ...tant Silent Panic Alarm Instant Silent Panic Alarm Instant Silent Panic Alarm Instant Silent Panic Alarm Instant Silent Panic Alarm Instant Silent Panic Alarm Instant Silent Panic Alarm Personal Att P...

Страница 56: ...lay will show you the triggered event directly Step 4 The display will show you the device that triggered the alarm with its zone number A l a r m S t a r t e d b y 0 1 I R H a l l w a y If there is m...

Страница 57: ...a r t e d b y C a n c e l Press OK to continue If the alarm is stopped after 90 sec the above display will not show Step 4A The screen will show C l e a r A l a r m D i s p l a y O K Step 5A Press OK...

Страница 58: ...tial Verification Alarm Reporting 4 15 1 Dual Ply Entry Warning z This is to warn the user that an alarm report to the Central Monitoring Station will be made z If a zone programmed as Entry or Away E...

Страница 59: ...ces to indicate their proper functioning If the Control Panel does not receive the signals transmitted from an individual sensor within the pre set Supervision time a Sensor out of order fault event w...

Страница 60: ...d manually after the fault condition has been rectified 4 16 3 Viewing Clearing the Fault Message To check what the fault condition is Step 1 When the system is in Alarm off mode Enter your PIN Code f...

Страница 61: ...l will report Battery Missing code 1311 to the Central Station in 24 hours When Battery is restored the Control Panel will report Battery Missing Restore code 3311 to the Central Station in 24 hours P...

Страница 62: ...orm as below Fault Condition Message displayed Interference Interference AC Power Fail AC failure Control Panel low battery Panel L B Control Panel sabotaged Panel Tamper Sensor Low Battery Sensor w Z...

Страница 63: ...d Power Switch Open for 1 Hour to 99 Hours 54101 54199 4th Power Switch Open for 1 Hour to 99 Hours 55101 55199 5th Power Switch Open for 1 Hour to 99 Hours 56101 56199 6th Power Switch Open for 1 Hou...

Страница 64: ...sage You can send it to the panel N NO OT TE E The panel will not send any message back to your handset 4 17 3 Test Confirmation Message When you finish programming the system you can use test message...

Страница 65: ...88 A First Priority To reset or change the telephone number 1 Max 30 digits TEL 2 see Note 3 TELN2 PROG 7982 TELN2 B026935288 B Second Priority To reset or change the telephone number 2 Max 30 digits...

Страница 66: ...To set final door option function 10 1 Area 1 0 function disable 20 2 Area 2 0 function disable Final Door FNLDR PROG 7982 FNLDR 11 21 11 1 Area 1 1 function enable 21 2 Area 2 1 function enable PROG...

Страница 67: ...for 0 sec 10 for 10 sec 70 for 70 sec 100 1 area 1 00 for 0 sec 240 2 area 2 40 for 40 secs PROG 7982 MCODE 12222 Master Code MCODE PROG 7982 MCODE 22222 To change master code 12222 1 Area 1 2222 new...

Страница 68: ...ble RCENT PROG 7982 RCENT 2 To set RC Entry Enable Option function for both Areas 0 RC Entry Enable option 1 RC Entry Enable on 2 RC Entry Enable off Remote Update REPGM PROG 7982 REPGM 1192 168 1 2 5...

Страница 69: ...NO OT TE E The name can be erased by clearing the display by entering backward spaces and pressing OK key 5 2 Reset Procedure Reset to Factory Default Setting The Control Panel can clear all programme...

Страница 70: ...ursts separated by spaces The Acknowledgement Tone is a single tone burst 5 4 1 Handshake Tone The Handshake Tone sequence is produced by the RECEIVER The purpose is to signal the Control Panel that t...

Страница 71: ...the tones shall be as follows Burst ON time 50 msec 50 min 60 max Burst OFF time 50 msec 50 min 60 max 5 4 8 Kiss off Acknowledgement Tone The Kiss off tone from the receiver is used to tell the Contr...

Страница 72: ...rms z 147 Sensor Supervisor Failure When CTC 1241 can t receive the signal transmitted from any one of the following devices individually for a period of the pre set Supervision time Door Contact PIR...

Страница 73: ...Guardian Code CTC 1241 will report event code 401 with Zone Number 016 Tel 1 account number or 024 IP 1 account number z 406 Panel Alarm Cancel z 407 Remote Arm Disarm z 408 Quick Arm Panel Terminal T...

Отзывы: