48
4.8.2. Arming the System via
Remote Controller
Step 1.
Press once on Full Arm or Home Arm
button.
Step 2.
Repeat steps 2-6 as described in
Arming the system via Control
Panel
.
<
<
N
N
O
O
T
T
E
E
>
>
)
For Exit Delay performance, please
refer to <IMPORTANT NOTE> on Exit
Delay Count Down Period under
section 4.2. Away Arm Mode.
)
The
Fault Display
screen has a time-
out of 2 minutes
and will then
automatically return to
Alarm Off
screen if no
OK
of Arming is
confirmed.
)
If a sensor is bypassed (please see
section 4.7. Bypass
), the fault
condition of that sensor will not be
checked.
)
If a sensor is tampered or out-of-order,
you can temporarily bypass it or
permanently remove it.
)
Force arming record can be checked
in the
Log
section.
4.8.3. Arming with Door Opened
z
While arming the system, if any Door
Contact is detected as Open, the Control
Panel will emit a ding-dong sound to
indicate arming is prohibited.
z
If user manually shuts the Door
immediately, the fault display will then be
automatically cleared and the screen
returns to
Alarm off
. You can then arm
the system again.
z
However, if you wish to put the system
into Arm mode with the door open, follow
the steps as described in
Section 4.8.
Force Arming
.
4.8.4. Arming with IR Triggered
z
While arming the system, if any PIR
Motion Detector is activated, the Control
Panel will prohibit the Arming within 5 sec
of its activation.
z
The user can only arm the system when
the IR is not activated.
4.8.5. Arming with Supervisory
Fault
z
The PIR sensor, Door Contact, Water
Sensor or Smoke Sensor, after installed,
will transmit a periodic supervision signal
at intervals between every 30 to 50 min.
z
When arming the system, if the Control
Panel has not received the Supervisory
Signal transmitted from any individual
sensor over a pre-setting period, a fault
event,
Lost of signal w/ sensor zone &
name
, will be displayed on the screen.
z
However, if you want to put the system
into Arm mode with the supervisory fault,
follow the Steps described in
Section 4.8
Force Arming
for operation.
4.9. Alarm Off Mode
If the system is in either the Away Arm mode or
Home Arm mode (Alarm ON), enter your pin
Code and press
OK
. If the PIN code is correct,
the Control Panel will sound 2 short beeps and
return to Alarm off mode. The display will show
both screens at every second flash.
A l a r m O
f f
0 0 : 0 1 0 1 J a n
<
<
N
N
O
O
T
T
E
E
>
>
)
When the system is Home Armed,
Day Home Armed or Night Home
Armed, pressing the
DISARM
button
on the Remote Controller will disarm
the system.
)
When the system is Away Armed,
pressing the
DISARM
button on the
Remote Controller can disarm the
sytem when either an
Entry
device
has been triggered, or when the
Remote Controller Entry Enable
has
been set to
ON
.
Содержание CTC-1241GT