97
diagnostic codes
DTC
How Set
Code Description
Brief Description
Software Parameters
Required to Set Code
Service Instructions /
Part Replaced
O R C
P0604
X
X
X
Internal Control Module Read
Only Memory (RAM) Error
This error occurs if a fault is detected in
the read only memory circuit.
PCM
P0605
X
X
X
Internal Control Module Read
Only Memory (ROM) Error
The checksum of the calibration ROM area is
checked and compared against an expected
value (calibration value) at startup.
Verify programming files, PCM
P061B
X
X
X
Internal Control Module Torque
Calculation Performance
This error occurs if a fault is detected when
monitoring the status of the injection of all cylinders
compaired to the current engine speed.
PCM
P061C
X
X
X
Internal Control Module
Engine RPM Performance
This error occurs when the engine RPM signal,
derived from the CKP circuit, differs significantly
from the expected engine RPM, developed by the
PCM, for a predetermined amount of time
PCM, CRK sensor, CRK wiring
P062D
X
X
Fuel Injector Driver Circuit
Performance Bank 1
This error occurs when the sum of the voltage signals for
the main injection of all injectors on bank 1 or if the fuel
injector driver circuit for bank 1 fails to initialize properly.
max = 229 V
min = 93 V
Wiring to injectors, PCM
P062E
X
X
Fuel Injector Driver Circuit
Performance Bank 2
This error occurs when the sum of the voltage signals for
the main injection of all injectors on bank 2 or if the fuel
injector driver circuit for bank 2 fails to initialize properly.
max = 229 V
min = 93 V
Wiring to injectors, PCM
P0620
X
Generator Control Circuit
P0625
X
Generator Field Terminal
Circuit Low
P0626
X
Generator Field Terminal
Circuit High
P0627
X
Fuel Pump A Control
Circuit / Open
This error occurs if electrical errors from the fuel
pump module result in an open circuit.
P0628
X
Fuel Pump A Control
Circuit Low
This error occurs if electrical errors from the fuel
pump module result in a short to ground.
P0629
X
Fuel Pump A Control
Circuit High
This error occurs if electrical errors from the fuel
pump module result in a short to power.
P0642
X
X
X
Sensor Reference
Voltage A Circuit Low
This error occurs when the sensor reference
voltage falls below the minimum threshold.
Low: < 4.75V
Wiring, PCM
P0643
X
X
X
Sensor Reference
Voltage A Circuit High
This error occurs when the sensor reference
voltage falls above a maximum threshold.
High: >5.25 V
Wiring, PCM
P065B
X
Generator Control Circuit
Range/Performance
P0652
X
X
X
Sensor Reference
Voltage B Circuit Low
This error occurs when the sensor reference
voltage falls below a minimum threshold.
Low: < 4.75V
Wiring to sensors, PCM
P0653
X
X
X
Sensor Reference
Voltage B Circuit High
This error occurs when the sensor reference
votage is above a maximum threshold.
High: >5.25 V
Wiring to sensors, PCM
P0670
X
X
X
Glow Plug Control Module
Control Circuit / Open
This error occurs if the glow plug enable circuit detects
an open circuit, short to ground, or short to power.
Internal to Glow Plug Control
Module (GPCM) > 5 sec
Wiring, GPCM, PCM
P0671
X
X
X
Cylinder 1 Glow Plug Circuit
This error occurs if the current for an individual glowplug
is either lower than the minimum current threshold
or higher than the maximum current threshold.
An open is a current level less
than 4 amps and a shorted
current level is above 60 amps.
Glow Plug on time > 8.5 sec
Wiring, Glow Plug, GPCM
P0672
X
X
X
Cylinder 2 Glow Plug Circuit
This error occurs if the current for an individual glowplug
is either lower than the minimum current threshold
or higher than the maximum current threshold.
An open is a current level less
than 4 amps and a shorted
current level is above 60 amps.
Glow Plug on time > 8.5 sec
Wiring, Glow Plug, GPCM
P0673
X
X
X
Cylinder 3 Glow Plug Circuit
This error occurs if the current for an individual glowplug
is either lower than the minimum current threshold
or higher than the maximum current threshold.
An open is a current level less
than 4 amps and a shorted
current level is above 60 amps.
Glow Plug on time > 8.5 sec
Wiring, Glow Plug, GPCM
P0674
X
X
X
Cylinder 4 Glow Plug Circuit
This error occurs if the current for an individual glowplug
is either lower than the minimum current threshold
or higher than the maximum current threshold.
An open is a current level less
than 4 amps and a shorted
current level is above 60 amps.
Glow Plug on time > 8.5 sec
Wiring, Glow Plug, GPCM
P0675
X
X
X
Cylinder 5 Glow Plug Circuit
This error occurs if the current for an individual glowplug
is either lower than the minimum current threshold
or higher than the maximum current threshold.
An open is a current level less
than 4 amps and a shorted
current level is above 60 amps.
Glow Plug on time > 8.5 sec
Wiring, Glow Plug, GPCM
Содержание 6.4L Power Stroke
Страница 3: ... This page intentionally left blank ...
Страница 5: ... This page intentionally left blank ...
Страница 6: ... 6 4L Power Stroke Diesel Direct Injection Turbocharged Diesel Engine ...
Страница 33: ...32 This page intentionally left blank ...
Страница 51: ...50 This page intentionally left blank ...
Страница 73: ...72 This page intentionally left blank ...
Страница 82: ...81 6 4l dit appendix TABLE OF CONTENTS Torque Charts 82 87 Wiring Diagram 88 89 Diagnostic Codes 90 101 ...
Страница 89: ...88 wiring diagram single alt reference only Refer to Ford Wiring Diagrams for Wiring ...
Страница 90: ...89 wiring diagram single alt reference only Refer to Ford Wiring Diagrams for Wiring ...
Страница 103: ...6 4L Power Stroke Diesel Engine Printed in U S A FCS 14853 MISC 2007 International Truck and Engine Corporation ...