4-40
4.2.1: Parameter default values and ranges depending on AC Drive model
Model
Frame
Maximum Output
Frequency (Hz) in
SLV Mode when
11-01 <= 8KHz
Maximum Output
Frequency (Hz) in
SLV Mode when
11-01 > 8KHz
Factory setting
of 11-01 in
HD mode
The maximum
value of 11-01
in HD mode
(SLV control
mode)
The maximum
value of 11-01
in HD mode
(Other control
modes)
20P5
1
150
150
5
16
16
2001
5
16
16
2002
2
150
150
5
16
16
2003
5
16
16
2005
5
16
16
27P5
3
150
150
5
16
16
2010
5
16
16
2015
4
110
110
5
16
16
2020
5
16
16
2025
5
100
80
5
8
12
2030
6
100
80
5
8
12
2040
5
8
12
4001
1
150
150
5
16
16
4002
5
16
16
4003
2
150
150
5
16
16
4005
5
16
16
47P5
3
150
150
5
16
16
4010
5
16
16
4015
5
16
16
4020
4
110
110
5
16
16
4025
100
100
5
16
16
4030
5
100
80
5
8
16
4040
6
100
80
5
8
12
4050
5
8
12
4060
5
8
10
4075
5
8
10