22-00
PM Motor Rated Power Default: KVA
Range
【
0.00–600.00
】
KW
22-02
PM Motor Rated Current Default: KVA
Range
25%–200% AC Drive’s rated current
22-03
PM Motor’s Pole Number Default: 8
Range
【
2–96
】
Poles
22-04
PM Motor’s Rated Rotation Speed Default: 1500
Range
【
6–65535
】
RPM
22-05
PM Motor’s Maximum Rotation Speed Default: 1500
Range
【
6–65535
】
RPM
22-06
PM Motor Rated Frequency Default: 75
Range
【
4.8–599.0
】
Hz
4-164
Output Torque (T)
Positive torque
Negative torque
Motor Speed
Forward
direction
Reverse
direction
21-08
21-05
21-06
21-07
I
II
III
IV
I:
II:
III:
IV:
Forward rotation positive torque
Reverse rotation positive torque
Reverse rotation negative torque
Forward Rotation negative torque
22 PM Motor Parameters
The PM parameter group can be restored to factory default by initializing the AC Drive (13-08). Set the motor rating
before initializing the AC Drive (13-00).
22-00: PM motor rated power
Set the motor power according to the motor nameplate.
22-02: PM motor rated current
Set the motor full load according to the motor nameplate.
22-03: PM motor pole number
Set the number of motor poles according to the motor nameplate.
22-04: PM motor rated speed
Set parameter 22-04 or 22-06, the AC Drive will automatically calculate one or the other. For more details see
parameter 22-06.
Set the motor rated speed in RPM according to the motor nameplate.