4-149
00040 - 39999
Set the decimal point by using the fifth place
i.e.
Sets full display scaling excluding decimals
Set the number of decimal places
00040 - 09999:
(Integer only e.g. 1000 )
10001 - 19999:
.
(1 decimal place e.g. 10.0)
20001 - 29999:
.
(2 decimal places, e.g. 10.00)
30001 - 39999:
.
(3 decimal places, e.g. 10.000)
<Example>:
16-03
Display
Display Unit
Display example
00040-09999
□□□□
Use 16-04
Setting
Example: 100 % speed is 0200
> set 16-03=00200 (from 05-01, 06-01 to 06-15, set
range from 0040 to 9999).
> set 16-04=0 (no unit)
10001–19999
□□□. □
Example: 100 % speed is 200.0 CFM
> set 16-03=12000 (05-01, 06-01 to 06-15, set range
from 0000 to 9999).
> set 16-04=2 (CFM)
> 60% speed will be displayed as 120.0 CFM
20001–29999
□□. □□
Example: 100 % speed is 65.00ºC
> set 16-03=26500 (05-01, 06-01 to 06-15, set range
from 0000 to 9999)
> set 16-04=20 (ºC)
> 60% of speed is displayed as 39.00 ºC
30001- 9999
□. □□□
Example: 100 % speed is 2.555 m/s
> set 16-03=32555
> set 16-04=14 (m/s)
> 60% speed is displayed as 1.533 m/s
16-04
: Display unit of engineering
When 16-03 = 00040 to 39999, engineering units are enabled. The displayed set range and the frequency range of
unit (05-01, 06-01–06-15) as well as the monitoring frequency (12-16, 12-17) are changed by parameters 16-04 and
16-03.
16-05
LCD Backlight Default: 5
Range
【
0–7
】
Adjust the screen backlight of the digital operator. If set to 0, the screen backlight is turned off.