4-15
Group 03 External Digital Input and Output Parameters
Param.
#
Parameter Name
Setting Range
Default
Unit
Control mode
Notes
V/F
SLV
PM/SLV
03-13
Freq. Detection Level
0.0–599.0
0
Hz
03-14
Freq. Detection Width
0.1–25.5
2
Hz
03-15
Current Agree Level
0.1–999.9
0.1
A
03-16
Current Agree Detection
Delay Time
0.1–10.0
0.1
s
03-17
Mechanical Braking
Release Level
0.00–599.00
0
Hz
(Note)
03-18
Mechanical Braking
Level Set
0.00–599.00
0
Hz
(Note)
03-19
Relay (R1A-R2A) Type
xxx0b: R1 A Contact
xxx1b: R1 B Contact
0000b
-
xx0xb: R2 A Contact
xx1xb: R2 B Contact
03-20
Internal / External Multi-
Function Input Terminal
Selection
0–63
0
-
03-21
Action To Set The
Internal Multi-Function
Input Terminals
0–63
0
-
03-22
Pre-Set Count 1
0–9999
0
-
03-23
Pre-Set Count 2
0–9999
0
-
03-24
Output Under Current
Detection
0: Invalid
0
-
1: Valid
03-25
Output Under Current
Detection Level
0–999.9
0.1
A
03-26
Output Under Current
Detection Delay Time
0.0–655.34
0.01
s
03-27
UP/DOWN Frequency
Hold/Adjust Selection
0: Hold last set frequency when
stopped
1: Set frequency to 0 when stopped
2: Allow speed changes from last set
frequency when stopped
3: Refresh frequency at acceleration.
0
-
03-30
Pulse Input
0: General Pulse Input
0
-
1: PWM
03-31
Pulse Frequency
50–25000
1000
Hz
*1
03-32
Pulse Input Gain
0.0–1000.0
100
%
*1
03-33
Pulse Input Bias
-100.0–100.0
0
%
03-34
Filter Time of Pulse Input
0.00–2.00
0.1
Sec
03-40
UP/DOWN Frequency
Width Setting
0.00–5.00
0.00
Hz
03-53
Current Agree Level 2
0.1–999.9
0.0
A
03-17 to 03-18
:
If the maximum output frequency of motor is over 300HZ, the frequency resolution is changed to
0.1Hz
*1:
Parameter can be changed while running.