FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 82 of 131
40100
R
1
Voltage of
Power Supply
Voltage of power supply is indicated with 0.1 V
increment.
e.g.: 23.4 VDC is indicated as integer 234 value.
40101
R
2
Ton/hour
indication
40103
R
10
Not used
40113
R
1
Process
Warning
Messages
Dec
Description
0
No process error
1
END
2-3
Not used
4
RESET
Process
Error Messages
128
E GATE
129
E TRNG
130
E TARE
131
E ZERO
132
E ZRNG
133
FiLL t
134
E VALV
135
E HOLE
136
Not used
137
NO FEED
40114
R
1
Process state
0
No Process (ADC out, Over, Under, etc.)
1
Ready
2
In filling process
3
End of filling (FULL)
4
In discharging process
42000
R/W
1
Filter
Refer to parameter [120] on page 34
42001
R/W
1
Not used
42002
R/W
1
Zeroing Range
Refer to parameter [203] on page 35
42003
R/W
1
Auto Zero Tracking
Refer to parameter [204] on page 35
42004
R/W
1
Tare
Refer to parameter [205] on page 35
42005
R/W
1
Motion Detector
Refer to parameter [206] on page 35
42006
R/W
2
Not used
42008
R/W
2
Capacity
Refer to parameter [212] on page 35
42010
R/W
1
Decimal point
Dec
Description
0
XXXXOO
1
XXXXXO
2
XXXXXX
3
XXXXX.X
4
XXXX.XX
5
XXX.XXX
42011
R/W
1
Increment
Dec
Description
1
X 1