FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 88 of 131
NS Network Status LED
LED State
Description
Comment
Off
Not online /No power
Check power and cable
Green
On-line (RUN)
-
Green, flashing
On-line (STOP)
-
12.1 Data Format
Data format of weight value can be programmable for Floating point (IEEE 754) or Integer. Refer to
parameter [060].
12.2 Profinet Parameters
There are 7 parameters for Profinet network and Profinet set up is done by IndFace1x (EtherX PC) software
over Local Network Area as described in this section. EtherX PC software is available on CD which is
supplied together with the instrument and under www.flintec.com.
Note:
Station name is ‘pn-io’ as a default.
DHCP
Dynamic Host Configuration Protocol automates network parameters if it is enabled.
Default is ‘Disable’.
IP Address
If DHCP is disabled, obtain IP address manually.
Default is ‘192.168.16.250’.
Subnet Mask
If DHCP is disabled, obtain subnet mask manually.
Default is ‘255.255.255.0’.
Default Gateway
If DHCP is disabled, obtain default gateway manually.
Default is ‘192.168.16.253’.
Primary DNS
If DHCP is disabled, obtain primary DNS manually.
Default is ‘208.67.222.222’.
Secondary DNS
If DHCP is disabled, obtain secondary DNS manually.
Default is ‘208.67.220.220’.
Host Name
Enter a unique host name to the instrument.
Default is ‘ ’.
12.3 GSDML Configuration and Data Structure
Profinet data structures of FT-10 FILL PN include 2 x Input 2 words and 2 x Output 2 words.
For Data Structure for Profinet see Appendix,
page 116
GSDML configuration for PLC programmers, same as for Profibus, is shown on Page 85.