FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 98 of 131
14.
CAN
OPEN
(
ONLY
FT-10
FILL
CO)
After setting related parameters to can communicate with the controller via CANopen network. EDS file is
available in CD which is supplied together with the instrument.
Automatically detected and supported baud rates are 10 kbps, 50 kbps, 100 kbps, 125 kbps, 250 kbps, 500
kbps, 800 kbps, 1 Mbps, Autobaud (default).
[07-] CANopen (Only FT-10 FILL CO)
This sub-block includes the parameters related with the CANopen interfaces of FT-10 FILL
controller.
[070 0] Data Format
0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied
[071 000] Rack Address
The CANopen rack address of FT-10 FILL will be entered via keypad between 001 to 126.
There are 2 LED’s near the CANopen connector which are;
Run LED
State
Indication
Comment
Off
Not online / No power
Check power and cable
Green
On-line, data exchange
-
Green, blinking
On-line, initializing
-
Green, single flash
Stopped
Check hardware damages
Green, flickering
Auto baud rate detection in
progress
-
Red
CANopen configuration error
Check EDS file
Error LED
State
Indication
Comment
Off
-
No power or CANopen module is in
initialization state
Red, single flash
Warning limit reached
A bus error counter reached or
exceeded its warning level
Red, flickering
LSS
LSS services in progress
Red, double flash
Error count event
A guard- (NMT-Slave or NMT-
master) or heartbeat event
(Heartbeat consumer) has occurred.
Red
Bus off (Fatal Event)
Bus off.
1
Run LED
2
Error LED
3
CANopen interface