FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 33 of 131
[05-] Profibus (Only FT-10 FILL PB)
This sub-block includes the parameters related with the Profibus interfaces of FT-10 FILL controller.
[050 0 ] Data Format
0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied
[051 000] Rack Address
The Profibus rack address of FT-10 FILL will be entered via keypad between 001 to 126.
[06-] Profinet, EtherNET/IP or EtherCAT (
Only FT-10 FILL PN, EI, EC)
This sub-block includes the parameters related with the Profinet interfaces of FT-10 FILL controller.
[060 0] Data Format
0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied
[07-] CANopen or CC-Link (Only FT-10 FILL CO, CC)
This sub-block includes the parameters related with the CANopen interfaces of FT-10 FILL
controller.
[070 0] Data Format
0 : Signed 32 bit integer, no decimal point implied
1 : 32 bit float, decimal point implied
[071 000] Rack Address
The CANopen rack address of FT-10 FILL will be entered via keypad between 001 to 126.
[072 000] Baudrate (only FT-10 FILL CC
0 : 156kbps
1 : 625kbps
2 : 2.5kbps
3 : 5Mbps
4 : 10Mbps