FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 61 of 131
Filling cycle
Press <
Zero
> key if the scale is not indicated zero after powered on. Apply start input to start feeding the
hopper. The two speed filling cycle is shown below. The [
FuLL
] prompt is displayed after end of the filling.
Emptying is start by “Bag is ready” input. After emptying, the following filling is started to go on the filling the
bag. After filling the target value in to the bag, the end prompt is displayed.
The target weight of each weighing cycle is calculated automatically to minimize the bag filling error.
Warning
:
Error correction frequency parameter [503] should be adjusted to 1 in this mode.
Notes
1) There is a preact adjustment delay only in preact adjustment frequency (refer to parameter [ 503 ] ).
2) The fine feed output is activate together with coarse feed output if parameter [ 501 ] is 1 as indicated in
the drawing above. If this parameter is adjusted to 0, the fine feed output is activated after coarse feeding.
Digital Inputs and Outputs Connection
I / O
Descriptions
Input 1
Start for filling
Input 2
Bag is ready
Input 3
Gate is closed
Input 4
Reset
Output 1
Coarse feeding
Output 2
Fine feeding
Output 3
Empty
Output 4
-
Output 5
End of bagging
E
Error
Z
at Zero range (refer to par. [117])