FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 24 of 131
4.3.12 Powerlink Connection (only FT-10 FILL PL )
Powerlink connection is done as indicated below in Figure 4.16.
Figure 4.20 - BX13 PL interface connections
Powerlink Connector pin configuration (RJ45)
Pin
Signal
DIR
Description
1
TX+
Out
Differential Ethernet transmit data +
2
TX−
Out
Differential Ethernet transmit data −
3
RX+
In
Differential Ethernet receive data +
6
RX−
In
Differential Ethernet receive data −
4
Not used
Terminated
5
Not used
Terminated
7
Not used
Terminated
8
Not used
Terminated
Shield
Chassis ground
The HUB connection cabling will be a direct connection as shown below:
Figure 4.21 - HUB connection
Warning:
Connect the shield to the reference ground or shield pin of the power connector.
Warning:
Disconnect IndFace1X PC software before starting Powerlink interfacing.