FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 118 of 131
Process error messages (always 32 bit integer)
1
st
Dword descriptions when read command is ‘Process error messages. Refer to 2
nd
Dword of PLC Output
to FT-10 FILL Input
Bit Number
1
st
Dword Description
D31 … D16
Not in use
D15 … D8
Process
State
Bin
Dec
Process state
00000000
0
No process (Adc out, Over, Under etc.)
00000001
1
Ready
00000010
2
In filling process
00000011
3
End of filling (FULL)
00000100
4
In discharging process
D7 ... D0
Process
Warning
Messages
Bin
Dec
Messages
00000000
0
No process error
00000001
1
END
00000010
00000011
2
3
Not used
00000100
4
RESET
Process
error
Messages
10000000
128
E GATE
10000001
129
E TRNG
10000010
130
E TARE
10000011
131
E ZERO
10000100
132
E ZRNG
10000101
133
FILL t
10000110
134
E VALV
10000111
135
E HOLE
10001000
136
Not used
10001001
137
NO FEED
Table 19.1
– Process error messages