FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 76 of 131
I
Read indicated weight
Command:
[ADR][I]
Response:
[ADR][I][STATUS][SIGN][WEIGHT VALUE]
Example:
Command: 01I
Response: 01IS+000123.4 (weight is stable and 123.4)
01ID+000123.4 (weight is dynamic and 123.4)
01I+
(overload)
Comments : Indicated weight value (stable or dynamic) is transmitted immediately.
The weight value may be in gross or net.
P
Print :Read the stable weight
Command:
[ADR][P]
Response:
[ADR][P][STATUS][SIGN][WEIGHT VALUE]
Example:
Command: 01P
Response: 01PS+000123.4
(weight is stable and 123.4) or
01PN
(could not print)
Comments : Checks status and it must be stable. Else Nack status is send.
Status can be Stable or Nack.
S
Read Status
Command:
[ADR][S]
Response:
[ADR][S][STATUS-1][STATUS-2][STATUS-3]
Example:
Command : 01S
Response : 01SSGI
(Stable, Gross, In Range)
01SDGL (Dynamic, Gross, Low voltage error)
Comments:
The response includes 3 status information.
STATUS-1 can be
S
table or
D
ynamic.
STATUS-2 can be
G
ross or
N
et.
STATUS-3
can be ‘
I
n range’, ‘
O
ut of range’, ‘
+
Over’, ‘
-
Under’, ‘
L
ow
voltage’, ‘
H
igh voltage’ or ‘
E
rrors’.
T
Tare
Command:
[ADR][T]
Response:
[ADR][T][A]
(Taring is done successfully, and scale is in net)
[ADR][T][N]
(Taring could not be executed)
[ADR][T][X]
(Taring is disabled)
Comments: The tare value is overwritten by the new tare weight value.
Status must be stable in 2 seconds time out delay. If so, Ack is send.
If it cannot be stable in time out delay, Nack is send.