FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 50 of 131
Filling cycle
Press <
Zero
> key if the scale is not indicated zero after powered on. Apply start input after loading the scale
with the container. The filling is done as indicated below. The [
FuLL
] prompt is displayed after end of the
filling and take off the container. After loading the next container press the start input again to fill it.
Notes
1) There is a preact adjustment delay only in preact adjustment frequency ( refer to parameter [ 503 ] ).
2) The fine feed output is activate together with coarse feed output if parameter [ 501 ] is 1 as indicated in
the drawing above. If this parameter is adjusted to 0, the fine feed output is activated after coarse feeding.
Digital Inputs and Outputs Connection
I / O
Descriptions
Input 1
Start of filling
Input 2
Valve is down
Input 3
-
Input 4
Reset
Output 1
Coarse feeding
Output 2
Fine feeding
Output 3
Valve down
Output 4
End of filling
Output 5
-
E
Error
Z
at Zero range (refer to par. [
117
])