FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 67 of 131
[
d_End ]
[ XX.X ]
Delay to release the bag
The bag catch output is released at the end of this delay after
feeding of bag stopped. The maximum is 25.0 seconds.
Enter the value by pressing
and
keys. Press the
key to enter the next parameter.
[
Gr-Net ]
[ XXXXX ]
Gross or Net filling
0 = Filling in gross. Zeroing manually.
1 = Zeroing the display after bag has been catched.
(refer to parameter [
505
] )
2 = Net filling.
Enter the value by pressing
and
keys. Press the
key to enter the next parameter.
Default is “0”.
Mode Related Display Messages :
The messages below are shown on the display in the filling cycle or if there is any error in the filling.
Display
Operation
[
StArt
]
Displayed from start input to the holding the bag output activating.
[
HoLd
]
Displayed during the bag catching. If bag clamp is not closed in 5
seconds, the “
E CLMP
” prompt will appear.
[
-Zero-
]
The prompt to indicate the zeroing process.
Refer to parameter [
506
].
[
FuLL
] [ XXXXX ]
Displayed end of the filling until bag clamp opening.
[
E ZEro
] [ XXXXX ]
The zeroing error message. The scale might be unstable or out of
the zeroing range.
Refer to parameter [
203
]) or parameter [
206
].
Press enter key to erase the Error message. Applying the start
input, the filling will be started even the zeroing is not available.
[
E CLMP
]
Bag holder error. Appears if the bag holder is not closed in 5
seconds.
[
E tArE
] [ XXXXX ]
Taring error. Appears if the taring is not done due to instability or
negative gross weight indication. The process restarted after start
entry.
[
nO FEEd
]
Feeding error. Displayed if the weight is not increased during
feeding the bag. Refer to Parameter [
508
].
[
FıLL t
]
Filling time error. The filling stops if the filling will not be finished in
given maximum filling time. Apply reset to erase the error. Refer to
parameter [