FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 93 of 131
40033
R
1
Calibratio
n Status
D0 .. D7
Calibration
Process
Status
Dec
Description
1
Ready for calibration
3
Zero calibration in process …
4
Span calibration in process …
9
Error (Refer to D8 ... D15)
D8 .. D15
Calibration
Errors
1
Calibration Timeout
- Restart calibration
2
ADC Error
- Re-energize the instrument
- If seen again, change the board.
3
Instrument cannot be calibrating
- Check load cell cable
- Re-energize the instrument
34
Instrument cannot be calibrating
- Load cell signal is very low or too high
35
Calibration Error
- Calibration loading is not enough
- Check test weight loading
- Check load cell connections
36
Calibration load value entry Error
- Test weight is too small. Increase the
test weight
37
Scale unstable
- Wait until scale become stable
- Check grounding wiring
38
The Calibration DIP switch is not ‘On’
position.
- Check the calibration DIP switch.
40034
R/W
6
Not used
40040
R/W
2
Process parameters
Mode 1
Mode 2
Mode 3
Mode 4
Mode 5
Mode 6
Mode 7
Mode 8
TARE¯¯
TARE¯¯
D_DISC
D_DISC
Not used
VibON
40042
R/W
2
TARE__
TARE__
D_GATE
D_GATE
Not used
VibOFF
40044
R/W
2
D_FILL
D_FILL
ZERO_R
ZERO_R
EXTRA
D_Hold
40046
R/W
2
Not used
SAFETY
Not used
L_TRGT
Not used
Gr-Net
40048
R/W
2
D_STRT
D_STRT
Not used
Not used
Not used
D_End
40050
R/W
2
S_TYPE
S_TYPE
Not used
Not used
Not used
Not used
40052
R/W
2
Not used
Not used
GAT_Ch
GAT_Ch
GAT_Ch
Not used
40054
R/W
17
Not used
40071
R
1
Actual weight (Net if the indication is in
Net)
(image of register 40001)
40072
R
1
Status
(image of register 40003)
40073
R
1
Tare weight
(image of register 40004)
40074
R
1
Gross weight
(image of register 40006)