![Flintec FT-10 FILL Скачать руководство пользователя страница 121](http://html1.mh-extra.com/html/flintec/ft-10-fill/ft-10-fill_technical-manual_2305534121.webp)
FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 120 of 131
PLC Output to FT-10 FILL Input
Bitwise of a Dword:
Dword
(R/W)
D31 D30 D29 D28 D27 D26 D25 D24 D23 D22 D21 D20 D19 D18 D17 D16
D15 D14 D13 D12 D11 D10 D9
D8
D7
D6
D5
D4
D3
D2
D1
D0
1
st
Dword
Next Dword defines the usage of this Dword.
2
nd
Dword
Not used
SFE Reset
Filling
Start
Not used
Expanded Commands List
Not in use
Command List
Read Data Selection
New
CMD
PLC Output to FT-10 FILL Input 2
nd
Dword
Bit Number
2
rd
Dword descriptions
D31 … D30
Not used
D29
Start for emptying (SFE)
A transition form 0 to1 activates the “Start for emptying” command.
D28
Reset
A transition form 0 to1 activates the “Reset” command.
D27
Start for filling
A transition form 0 to1 activates the “Start for filling” command.
D26 … D24
Not used
D23 … D16
Expanded Commands List (Refer to Fehler! Verweisquelle konnte nicht gefunden w
erden.)
D15 … D11
Not in use
D10 … D6
Command
List
Bin
Dec
Commands
00000
0
None command is activated
00001
1
Zero
00010
2
Tare
00011
3
Clear
00100
4
00101
5
Adjust zero calibration
Calibration
00110
6
Adjust span calibration
(1)
00111
7
Total Load Cell Capacity
(1)
eCal
Coefficients
Refer to par.
[313]
01000
8
Average mV/V value
(1)
01001
9
Dead Load value
(1)
01010
10
Save the coefficients of eCal
01011
10000
11
16
Not used
10001
17
Target value
[ 1 ]
10010
18
Not used
10011
19
Coarse value
[ 1 ]
10100
20
Not used
10101
21
Fine value
[ 1 ]
10110
22
Label number (CN) (always integer)
[ 1 ]
10111
23
Not used
11000
24
Quantity (always integer)
[ 1 ]
11001
25
Total
[ 1 ]