6.3 Mode 3: Bung-Type Container Filling as Gross
Typical Application
•
Container which has bunghole filling in gross.
•
Tin, drum filling machines.
Operation
•
After receiving start input or automatically, filling
valve goes through hole of the container.
•
Filling starts and is executed as 2 speeds
directly into a container as above surface.
•
At the end of feeding, the valve runs out of the
container. Process ends when the filled
container removed from the platform.
Mode Related Filling Parameters
The mode related filling parameters shall be entered before start up the filling. Please enter the values
below carefully for better filling performance of the filling machine.
Display
Operation
[
123.456
kg ]
Press long
key, [
tArE_ _
] message appears.
[
tArE _ _ ]
[XXXXX]
Minimum tare value.
Filling can start if the weight of the container
is bigger than this value. Enter minimum tare value by pressing
and
keys. Press the
key to go to the next
parameter.
[
tArE ¯ ¯ ]
[XXXXX]
Maximum tare value.
Filling can start if the weight of the container
is lower than this value. Enter maximum tare value by pressing
and
keys. Press the
key to go to the next
parameter.
[
SAFEtY]
[XXXXX]
Safety.
If filling valve doesn’t go through hole of the container, this
parameter saves the system. While the filling valve is moving down,
if the weight is bigger than safety weight, valve moves up and filling
does not start. Condition : Safety > Maximum tare value.
Enter safety weight by pressing
and
keys. Press the
key to go to the next parameter.
[
d_
FıLL ]
[ XXXXX ]
Filling Start delay.
This parameter delays the feeding after
applying start input or automatic start. Enter start delay value by
pressing
and
keys. Press the
key to go to the next
parameter.
Maximum value is 9.9 seconds. Default is 0.0 seconds.
[
d_Strt ]
[ XXXXX ]
Auto start control delay.
This parameter delays after weight
bigger than minimum tare value and filling starts automatically at
the end of this delay. Enter the value by pressing
and
keys. Press the
key to go to the next parameter. Maximum
value is 9.9 seconds. Default is 0.0 seconds.
[
S_tYPE ]
[ XXXXX ]
Start type.
0 = Manual. Filling starts by input or fieldbus.
1 = Automatic. Filling starts when weight is bigger than Minimum
tare value.
Enter Start type by pressing
and
keys. Press the
key to go back to the operation. Default is 0.