FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 63 of 131
6.7 Mode 7: Weight-in / Weight-out
Typical Applications
•
Filling of materials, which has high viscosity
•
Multi-scale batching systems which are
feeding the conveyor or mixer by measuring
at discharge.
Operation
Filling:
•
Apply filling start input for weighing- in.
•
One speed filling to the ( [
EXtrA
] + Target ).
•
End of filling output is activated and [ Full ]
prompt is displayed.
Discharging;
•
Apply discharge start input.
•
Feeding is done in 2 speeds after feeding
gate checking.
•
End of discharge output is activated after
end of discharge.
Mode Related Filling Parameters:
The mode related filling parameters shall be entered before starting up the filling. Please enter the values
below carefully for better filling performance of the filling machine.
Display
Operation
[
123.456
kg ]
Press long
key, [
EXtrA
] message appears.
[
EXtrA ]
[ XXXXX ]
Extra weight
Enter the value, that will remain on the scale after discharging.
Weight-in = Extra
Enter the value by pressing
and
keys. Press the
key enter the next parameter.
[
GAT_Ch ]
[ X ]
Feeding gate position check
0 = No gate switch
1 = Gate switch function is enabled
Enter gate position check value by pressing
and
keys.
Press the
key to go back to the operation.
Default is “0”.
Mode Related Display Messages:
The messages below are shown on the display in the filling cycle or if there is any error in the filling.
Display
Operation
[
ChArGE
]
Displayed at the beginnig of filling for 1 second.
[
FuLL
] [ XXXXX ]
Announces the end of filling until discharge.
[
dSChrG
]
Displayed at the beginnig of discharge for 1 second.
[
E tArE
] [ XXXXX ]
This message appears if Taring is not possible.
For example, if the weight is negative or scale is not stable. It is
shown alternately by the weight value. When the conditions
become normal, error is acknowledged by Start Input.