FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 105 of 131
Expanded Command List (always 32 bit integer)
Here TxPDO 1 (T_UL1) is the data receiving from PLC and the “D48 … D55” bits describes below.
Bit No
Description
D48…D55
Expanded
Commands
List
Bin
Dec
Commands
00000000
0
R
Voltage of
Power Supply
Voltage of power supply is
indicated with 0.1 VDC
increment.
00000001
00011111
1
31
Not in use
00100000
32
R/
W
Process parameters
(1 )
Mode-1
Mode-2
Mode-3
Mode-4
Mode-5
Mode-
5
Mode-
6
Mode-
7
TARE¯
¯
TARE¯
¯
D_DIS
C
D_DIS
C
Not
used
VibON
00100001
33
R/
W
TARE_
_
TARE_
_
D_GAT
E
D_GAT
E
Not
used
VibOFF
00100010
34
R/
W
D_FILL
D_FILL
ZERO_
R
ZERO_
R
D_Hold
00100011
35
R/
W
Not
used
SAFET
Y
Not
used
L_TRG
T
Not
used
Gr-Net
00100100
36
R/
W
D_STR
T
D_STR
T
Not
used
Not
used
Not
used
D_End
00100101
37
R/
W
S_TYP
E
S_TYP
E
Not
used
Not
used
Not
used
Not
used
00100110
38
R/
W
Not
used
Not
used
GAT_C
h
GAT_C
h
Not
used
00100111
00111111
39
63
Not used
01000000
64
R/
W
Filter
(1)
Refer to par. [120], page 34
01000001
65
Not used
01000010
66
R/
W
Zeroing Range
(1)
Refer to par. [203], page 35
01000011
67
R/
W
Auto Zero
Tracking
(1)
Refer to par. [204], page 35
01000100
68
R/
W
Tare
(1)
Refer to par. [205], page 35
01000101
69
R/
W
Motion Detector
(1)
Refer to par. [206], page 35
01000110
01000111
70
71
Not used
01001000
72
R/
W
Capacity
(1)
Refer to par. [212], page 35
01001001
73
R/
W
Decimal point
(1)
0
XXXXOO
1
XXXXXO
2
XXXXXX
3
XXXXX.X
4
XXXX.XX
5
XXX.XXX
0100101
0
74
R/
W
Increment
(1)
1
X1
2
X2
3
X5