FT-10 Fill Technical Manual, Rev. 2.21, July 2020
Page 34 of 131
5.4.2 Configuration Block [1--]
In this block the parameters take place which are being used to set FT-10 FILL according to your
application.
[116 3] Function key
This
key function is programmed as;
0 : No any
1 : Total
2 : 1/hour (ton/hour or klb/hour) indication
3 : Quantity
4 : Last filling value
Explanation
:
If this parameter is selected as total or quantity, to clear the weight the <Clear> key must be
pressed while the weight value is displayed. [Clear] will appear on the display. Confirm by pressing <Enter>
key or cancel by pressing <F> key.
[117 0 ] Zero Range Output
0 : Active if weight value is in gross zero
( -1e < W
G
< +1e )
1 : Active if indicated weight value is zero
( -1e < W < +1e )
2 : Active if indicated weight value is in centre of zero
( -0,25e < W < +0,25e )
[12-] Filter
In this block the proper filter values according to the operating conditions can be entered. One of the
most important features of FT-10 series is viewing filter characteristic on the display and with the
help of this option, you can select the most suitable filter without exiting the programming mode.
[120 7 ] Filter
The filter value can be selected from 0 to 9 (The minimum value of the filter, at least 7 in normal
weighing applications). As you enter this parameter and press <
Enter
> key while [
120 X
] seen on
the display, the weight variation can be seen on the display. The value of the filter can be changed
by using <
> key and the weight variation for every value can be seen on the display. After finishing
the filter selection you can go to next step by pressing the <
F
> key.
[14-] Entries
In this block you can enter the initial CN.
[142 ] Label No (CN)
[ XXXXXX ]
The desired value is entered via <
Tare
> and <
Zero
> keys and saved by pressing <
Enter
> key. If
the number exceeds 65535, it will automatically reset and begin from 1 again.
[143 1] Display Refresh Rate
0 : 60ms
1 : 100ms
2 : 200ms
3 : 300ms
4 : 400ms
5 : 500ms
6 : 600ms
7 : 700ms
8 : 800ms
9 : 900ms