Power supply cord gauge
18 AWG (0.82mm
2
) copper stranded
Efficiency 83%
Heat dissipation (DVT)
51
Power consumption (DVT)
51
Acoustic noise (in dBA per ISO 7779)
47 (high fan speed)
37 (low fan speed)
Summit X250e-48p Power & Acoustic Sound
Operational voltage range
85 to 264 V~
Nominal input ratings
100 to 240 V~, 50/60 Hz, 5.5 A
Input current
5.25 A @ 115 V~ (low-line)
2.5 A @ 230 V~ (high-line)
Line frequency range
47 to 63 Hz
Inrush current
30 A @ 115 V, 60 A @ 230 V
Power supply cord type
AC
Power supply input socket
IEC 320 C14
Power cord input plug
IEC 320 C13
Power cord wall plug
Refer to
“Power Supply Cords Selection” on page 375
.
Power supply cord gauge
18 AWG (0.82 mm
2
) copper stranded
Efficiency
78%
Heat dissipation (DVT)
130
Power consumption (DVT)
520
Acoustic noise (in dBA per ISO 7779)
46 (high fan speed)
39 (low fan speed)
Safety Standards
North American Safety of ITE
UL 60950-1:2003 1st Ed., Listed Device (US)
CSA 22.2#60950-1-03 1st Ed.(Canada)
Complies with FCC 21CFR 1040.10 (US Laser Safety)
CDRH Letter of Approval (US FDA Approval)
IEEE 802.3af 6-2003 Environment A for PoE Applications
European Safety of ITE
EN 60950-1:2001+A11
EN 60825-1+A2:2001 (Lasers Safety)
TUV-R GS Mark by German Notified Body
73/23/EEC Low Voltage Directive
International Safety of ITE
CB Report & Certificate per IEC 60950-1:2001 Country Deviations
AS/NZX 60950-1 (Australia /New Zealand)
EMI/EMC Standards
North America EMC for ITE
FCC CFR 47 part 15 Class A (USA)
ICES-003 Class A (Canada)
European EMC standards
EN 55022:1998 Class A
EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11
EN 61000-3-2,3 (Harmonics & Flicker)
ETSI EN 300 386:2001 (EMC Telecommunications)
89/336/EEC EMC Directive
Table 82: Summit X250e series switch technical specifications (Continued)
Содержание BlackDiamond 10808
Страница 14: ...Table of Contents Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 14 ...
Страница 18: ...Preface Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 18 ...
Страница 19: ...1 Site Preparation ...
Страница 20: ......
Страница 40: ...Site Preparation Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 40 ...
Страница 41: ...2 BlackDiamond Switches ...
Страница 42: ......
Страница 68: ...BlackDiamond 8800 Modules Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 68 ...
Страница 92: ...BlackDiamond 10808 Series Modules Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 92 ...
Страница 93: ...3 Installing BlackDiamond Switches and Modules ...
Страница 94: ......
Страница 189: ...4 Installing BlackDiamond Switch Accessories ...
Страница 190: ......
Страница 206: ...BlackDiamond Cable Management Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 206 ...
Страница 207: ...5 BlackDiamond Maintenance Procedures ...
Страница 208: ......
Страница 239: ...6 Summit Family of Switches ...
Страница 240: ......
Страница 278: ...Summit Family of Switches Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 278 ...
Страница 335: ...7 Optics ...
Страница 336: ......
Страница 363: ...8 Initial Management Access ...
Страница 364: ......
Страница 368: ...Initial Management Access Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 368 ...
Страница 369: ...9 Appendixes ...
Страница 370: ......
Страница 414: ...Technical Specifications Extreme Networks Consolidated ExtremeXOS Hardware Installation Guide 414 ...