40
MP500/4N-8-16 Programming
4.12.2
Output types
The physical features of the outputs can be changed during programming.
Possible output types are:
Not used
: this disables the output.
Output N.L.
: (in stand-by) if this is a relay output it will be de-energised, if this is an electric output it will be open (without potential).
Output N.H.
: (stand-by) if the output is a relay it will be energised; if the output is a positive reference electric output it will be set to
12 V level; if the output is negative reference output, it will be set to level 0 V.
See the
Instruction Manual
for a detailed analysis of relay and electric outputs when set to N.L. or N.H.
WARNING!
For the correct functioning of the system, it is recommended
not to modify
the default programming (N.H.) for the
control panel outputs (UC.U1, UC.U2, etc ...).
4.12.3
Output assignment
Each output may be assigned to the entire system, i.e. to all partitions, or only to some partitions.
The output is activated only by events or inputs which concern the assigned partitions.
4.12.4
Output customisations
The control panel and expansion outputs (both electric and relay) may be programmed to be activated after given events.
Detail of events and management
shows when and how an output is activated.
How to use TC outputs
The TC (Trigger Control) output is used to control detectors, sirens and other indicator devices, putting them in stand-by, for example,
and is conditioned by the partition state.
The AND TC input means that all assigned partitions must be armed for the output to be activated.
For an OR TC it is sufficient for one of the assigned partitions to be armed for the output to be activated.
IMPORTANT!
The TC output is set to N.H. and with polarisation jumper set to “
+
” by default. A high level is provided in stand-
by in this manner (+12 V).
The possible customisations for EN50131 compliant outputs are described below.
O BURGLAR ALARM
The burglar alarm output is activated if a burglar event is generated.
O PRE-ALARM
The pre-alarm output is activated if a pre-alarm event is generated.
O RESET BURGL.AL
The reset burglar alarm output is activated in pulse mode for approximately 1 second when the partitions are armed.
O TAMPER
The tamper output is activated if a tamper event, or a wrong code event or a radio jamming event or a no radio supervision event
occurs.
O SYSTEM FAILURE
The system failure output is activated when a system failure alarm is generated (siren failure, external communicator error, no interface
on bus).
O TEL. FAILURE
The telephone failure alarm output is activated if a telephone fault event is generated.
O LOW BATTERY
The low battery output is activated when a no battery or inefficient battery event is detected.
O LACK OF POWER
The blackout output is activated if a "lack of power" event is generated.
O BUZZER
The buzzer output beeps slowly during the Exit Time and beeps rapidly during the Entry Time to partitions assigned to it.
O PARTIT. STATUS
The partition status output is activated when all the partitions assigned to it are armed.
O AND TC
The AND TC output is activated when all the partitions assigned to it are armed.