MP500/4N-8-16 Programming
105
7.2.13
Failure alarm from failure input
Monitoring of devices provided with fault output can be implemented in combination on control panels.
This is generated
when...
A programmed failure input is opened.
The alarm is generated regardless of partition status (H24).
It activates...
The programmed failure outputs which have at least one partition in common with the input which
generated the event.
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call,
text message or modem communication.
It is stored...
In the Event Log and the Diagnose Log.
In the faults and anomalies list.
It is indicated...
On fault LED of keypads which have at least one partition in common with the input which generated the
event.
On readers which have at least one partition in common with the input which generated the event.
It is stopped by...
Closing the programmed failure input again.
After having solved the
problem, the control
panel...
Activates the dialler to send the respective failure alarm message (if programmed) in form of numeric
code, vocal call, text message or modem communication.
Stores the end of failure in the Event Log and in the Diagnose Log.
Deactivates the programmed failure outputs.
7.2.14
System failure alarm
This is generated
when...
An anomaly concerning the system power occurs.
An anomaly concerning the battery charging circuit occurs.
An anomaly concerning the sirens occurs.
An anomaly concerning the supplementary power supply occurs.
The alarm is generated regardless of partition status (H24).
It activates...
The programmed system failure outputs.
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call or
modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On The yellow fault LED on the keypads.
It is stopped by...
Solving the problem.
After having solved the
problem, the control
panel...
Stores end of fault in the Diagnose Log.
Activates the dialler to send the respective end of failure alarm message (if programmed) in form of
numeric code, vocal call or modem communication.
Deactivates the programmed system failure outputs.
7.2.15
External communicator failure alarm
This is generated
when...
An external communicator failure input is opened.
The alarm is generated regardless of partition status (H24).
It activates...
The programmed communicator failure outputs.
The dialler to send the respective alarm message (if programmed) in form of numeric code, vocal call or
modem communication.
It is stored...
In the Diagnose Log and in the fault and anomaly memory.
It is indicated...
On The yellow fault LED on the keypads.
On The red LED of the readers.
It is stopped by...
Solving the problem.
After having solved the
problem, the control
panel...
Stores end of fault in the Diagnose Log.
Activates the dialler to send the respective end of failure alarm message (if programmed) in form of
numeric code, vocal call or modem communication.
Deactivates the programmed tel. failure outputs.
Содержание MP500/16
Страница 139: ...MP500 4N 8 16 Programming 139 ...