78
MP500/4N-8-16 Programming
10) The status LED will light up after 5 seconds (fixed if all partitions are armed, blinking if only some
partitions are armed). The square will appear full indicating the partitions which have been armed. The
following will appear on the display:
IMPORTANT!
The user will arm only the assigned partitions and not necessarily all the partitions
even with this procedure.
11) The display will go back to standard view automatically after one minute after arming both areas and
partitions. Press
to go to standard display immediately.
12) For arming both areas and partitions, if programmed or if the system is EN50131 grade 3 compliant,
the keypad will sound long beeps initially followed by short beeps for the last 10 seconds.
5.4
ARMING WITH ELECTRONIC OR PROXIMITY KEY
5.4.1
Total arming from electronic key reader
IMPORTANT!
This procedure can only be used if all partitions are disarmed.
5.4.1.1
System in use mode = Mode 3 (EN50131 grade 3 compliant)
Proceed as follows to arm all partitions assigned to the reader and to the key using the electronic key:
1. Insert the electronic key in the reader. The red LED will blink to indicate that the key is being read and the green L ED will light up
after a few instants to indicate that the key was recognised. All the green LEDs will blink rapidly if the key is not recognised.
2. The green LEDs corresponding to the armed partitions, if any, will appear if the key is recognised. The red LED will keep blinking.
3. Extract the key.
4. Insert the electronic key again when the red LED switches off.
5. Extract the electronic key when the red LED starts blinking.
6. The green LEDs will blink for a few seconds and the partitions associated to the reader and to the key will be armed.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
5.4.1.2
System in use mode = Mode 2 or Mode 0
Proceed as follows to arm all partitions assigned to the reader and to the key using the electronic key:
1. Insert the electronic key in the reader when all the green LEDs are off (the procedure will disarm the partitions if any LEDs are
green). The red LED will blink to indicate that the key is being read. All the green LEDs will blink rapidly if the key is not recognised.
2. Extract the electronic key when the red LED starts blinking.
3. The green LEDs indicate the status of the partitions assigned to the reader.
LED on fixed
= partition armed,
LED off
= the key is not
assigned to the partition and cannot arm it.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
5.4.2
Total arming from proximity key reader
IMPORTANT!
This procedure can only be used if all partitions are disarmed.
5.4.2.1
System in use mode = Mode 3 (EN50131 grade 3 compliant)
Proceed as follows to arm all partitions assigned to the reader and to the key using the proximity key:
1. Approach the proximity key to the transponder. The red LED will blink to indicate that the key is being read and the green LED will
light up after a few instants to indicate that the key was recognised. All the green LEDs will blink rapidly if the key is not recognised.
2. The green LEDs corresponding to the armed partitions, if any, will appear if the key is recognised. The red LED will keep blinking.
3. Move the key away.
4. Approach the proximity key again when the red LED switches off.
5. Move away the proximity key when the red LED starts blinking.
6. The green LEDs will blink for a few seconds and the partitions associated to the reader and to the key will be armed.
IMPORTANT!
The key will arm only the assigned partitions and not necessarily all the partitions even with this procedure.
EXECUTED