38
MP500/4N-8-16 Programming
6) Press
.
7) Change the logical address using keys
and the numeric keypad. Press
to confirm.
IMPORTANT!
There cannot be two inputs with the same logical address.
8) Press
.
9) Press
.
10) Press
and
to select the required input type. Press
to confirm.
11) Press
.
12) Press
. Press
and
to assign the input to the SYSTEM (all partitions) or only to some
PARTITIONS. Press
to confirm.
13) If SYSTEM is selected, press
and
to select SYSTEM ASSIGN or SYSTEM DO NOT
ASSIGN and press
to confirm. Then
.
14) A representation of the partitions will appear if PARTITIONS is selected. The empty boxes
represent partitions which are not assigned to the input and the black boxes the partitions which
have already been assigned. Press
and
to select the partition to be associated. Press
and
to assign the partition (the square will turn black) or to disassociate it (the square will
appear empty). Repeat the procedure for all partitions to be associated to the input.
15) After having assigned the partitions, press
, then
and
.
16) Press
. Press
and
to customise the input customisation. The delay (5 s, 10 s, 20 s, 30
s, 1 min, 1 min 30 s, 5 min) can be selected if DELAY is selected.
IMPORTANT
!
The delay cannot be longer than 45 second to maintain EN50131 compliance.
An arming delay time must be set and this cannot be longer than 45 second to be EN50131
compliant. So, DISABLED, 1 min, 1 min 30 s, 5 min cannot be selected.
17) Confirm the choice by pressing
and press
.
18) Press
. Press
and
to enable or disable the input as isolable. Press
to confirm.
19) Press
and then
. Press
and
to select the ancillary function (none, absence of
move, gong, courtesy light, door opener). Press
to confirm.
20) Press
.
21) Press
. Press
and
to select whether to release the alarm after the first or the second
opening of the input (single, double). Press
to confirm.
22) Press
.
23) Press
. Press
and
to select how the status of the partitions which have the input in
common must be considered for alarm purposes. Press
to confirm.
LOGIC NUMBER
IN001:...
UC.In1: In001
INPUT TYPE
INPUT TYPE
N.C. DOUBLE BAL.
UC.In1: In001
ASSIGN
ASSIGN
SYSTEM
SE##:
□□□□□■□
UC.In1: In001
CUSTOMIZE
CUSTOMIZE
1ST ENT/LST EXIT
UC.In1: In001
ISOLABLE
ISOLABLE
ENABLE
UC.In1: In001
ANCILLARY FUNCT
UC.In1: In001
ATTRIBUTES
ATTRIBUTES
RELEASE TYPE
ATTRIBUTES
COMMON INPUT
COMMON INPUT
AND PARTITIONS