MP500/4N-8-16 Programming
45
8) Press
.
9) Press
. Press
and
to enable or disable the keypad gong function. Press
to confirm.
10) Press
.
11) Press
. Press
and
to enable or disable the entry time sound. Press
to confirm.
IMPORTANT!
The Entry Time sound indication is mandatory for EN50131 grade 3
compliance.
12) Press
.
13) Press
. Press
and
to enable or disable the exit time sound. Press
to confirm.
IMPORTANT!
The Exit Time sound indication is mandatory for EN50131 grade 3
compliance.
14) Press
.
15) Press
. Press
and
to enable or disable masking. Press
to confirm.
IMPORTANT!
Do not enable masking to maintain EN50131 compliance. The LEDs are
managed directly by the control panel.
16) Press
.
17) Press
. Enter a descriptive name for the keypad using the keypad (see paragraph
). The name can be up to 24 characters long. Press
to confirm.
18) Press
.
19) Press
. Press
and
to select the concerned function. Press
to confirm.
20) Press
and
to enable or disable the function key. Press
to confirm.
21) Repeat the procedure from step 19 to enable the other function keys.
22) Press
to program the other keypads repeating the procedure from step 3.
23) Press
repeatedly to exit from the menu.
IMPORTANT!
Program all the keypads used by the system.
KP01:KP 01
GONG FUNCTION
GONG FUNCTION
DISABLE
KP01:KP 01
SOUND TIME ENTRY
KP01:KP 01
SOUND TIME EXIT
KP01:KP 01
MASKING
KP01:KP 01
NAME
NAME
KP01:KP 01
KP01:KP 01
FUNCTION KEYS
FUNCTION KEYS
FIRE ALARM
Содержание MP500/16