MP500/4N-8-16 Programming
5.3
ARMING FROM KP500DP/N KEYPAD
– KP500D/ST
5.3.1
Total arming (system with partitions only)
Proceed as follows to arm the entire alarm system if no areas are defined:
1) Enter < Master / User code > and press
2) The keypad will beep. Press
to exit without arming. The status LED will light up after 5 seconds
(fixed if all partitions are armed, blinking if only some partitions are armed). The square will appear full
indicating the partitions which have been armed. The following will appear on the display:
3) Press
again if you do not want to wait for 5 seconds.
4) The display will go back to standard view automatically after one minute. Press
to go to standard
display immediately.
5) If programmed or if the system is EN50131 compliant, the keypad will sound long beeps initially
followed by short beeps for the last 10 seconds.
IMPORTANT!
The user will arm only the assigned areas and not necessarily all the areas even with this procedure.
5.3.2
Total arming (system with areas and partitions)
Proceed as follows to arm the entire alarm system if areas are defined:
1) Enter
<Master / User / Installer / Technical Manager code >
and press
.
2) Press
F1
for areas or
F4
for partitions. Press
F1
(i.e. areas) on the display. An empty square will appear
for each programmed area which is not armed assigned to the keypad and code. Full squares indicate
that the area is armed. Half-full squares indicate that the area is only partially armed.
3) The keypad will beep. Press
to exit without arming. The status LED will light up after 5 seconds
(fixed if all areas are armed, blinking if some areas are not armed). The squares will appear full
indicating the areas which are not armed. The following will appear on the display:
4) Press
again if you do not want to wait for 5 seconds.
IMPORTANT!
The user will arm only the assigned areas and not necessarily all the areas even
with this procedure.
5) If
F4
(i.e. partitions) was pressed instead, an empty square will appear on the display for each
programmed partition which is not armed assigned to keypad and code. Full squares indicate that the
partition is armed. Octagons (e.g.
)
indicate that the partition is disarmed and some inputs are open.
6) The keypad will beep. Press
to exit without arming. The status LED will light up after 5 seconds
(fixed if all partitions are armed, blinking if only some partitions are armed). The square will appear full
indicating the partitions which have been armed. The following will appear on the display:
7) The display will go back to standard view automatically after one minute after arming both areas and
partitions. Press
to go to standard display immediately.
8) For arming both areas and partitions, if programmed or if the system is EN50131 compliant, the keypad
will sound long beeps initially followed by short beeps for the last 10 seconds.
ARM
EXECUTED
EXECUTED
ARM
EXECUTED
ARM
ARM