MP500/4N-8-16 Programming
11
1.1.2.1
Use of LEDs with EN50131 grade 3
The keypad LED indications which are visible without needing to enter a valid code depend on the EN50131 grade (Mode 3, Mode 2 or
Mode 0) set during programming.
IMPORTANT !
By setting Mode 0 the system will lose EN50131 compliance it potentially had before.
Behaviour in Mode 2 is two-fold: all LED indications are visible when the alarm system is disarmed, while only the power, timed
programmer and system status indications appear when the system is armed (the other LED indications may be viewed by entering a
valid code). This mode is EN50131 grade 2 compliant.
The alarm system is EN50131 grade 3 compliant in Mode 3. LED indications are not always visible and depend on system status
(armed or disarmed) and whether a valid access code is entered. The indications shown refer to the partitions associated to the keypad
only.
IMPORTANT !
Mode 3 is not available for the MP500/4N control panel because this device is EN50131 grade 2, and not
grade 3, compliant.
Table 4 - LED indication visibility of KP500D/N and KP500DV/N keypads complying with EN50131 grade 3
on the keypad in Mode 3.
Enter a valid code to see details on the indications.
All indications can be deleted using the Installer or Technical Manager codes. Only burglar, power failure and communication failure
indications can be deleted with the Master or User codes.
Alarm system status
Armed
Disarmed
Access code used
No code
Master / User
Installer /
Technical
Manager
No code
Master / User
Installer /
Technical
Manager
Power LED
■
■
■
■
■
■
Failure or warning LED
□
□
■
■
■
Maintenance LED
□
□
■
■
■
Timed programmer LED
■
■
■
■
■
■
Open inputs LED
□
□
■
■
■
Inhibited or isolated input LED
□
□
□
□
Alarm LED
□
□
□
□
Tamper LED
□
□
□
□
System status LED
□
□
□
□
■
= The LED indication is always visible even without entering an access code.
□
= The LED indication is only visible after having entered a valid access code.
Table 4 - LED indication visibility of KP500D/N and KP500DV/N keypads complying with EN50131 grade 3
1.1.3
Partition indications
The partition status is shown on the display in graphic mode.
The graphic symbols corresponding to digits 1 to 16 appear on the second line of the screen.
The meanings are:
Symbol
During normal use
During programming
□
partition disarmed
partition not associated to the function
■
partition armed
partition associated to the function
0
partition disarmed with one or more open inputs
-
.
partition does not exist
partition does not exist
Example for MP500/16
Partition 4 is armed, partitions 1, 2, 5 and 6 are disarmed, partition 3 is disarmed with one or more
open inputs, partitions from 7 to 16 do not exist.
SYSTEM STATUS
□□□□□□..........
SYSTEM STATUS
□□0■□□..........
1 2 3 4 5 6 7 8 9 10 1112131415 16
1 2 3 4 5 6 7 8 9 10 1112131415 16
Содержание MP500/16