20
MP500/4N-8-16 Programming
2 - SYSTEM ACCESS
This chapter contains a description of the available system access codes, functions and programming.
2.1
SYSTEM ACCESS CODES
Access to given system functions is permitted according to the access code type (Master, User, Installer or Technical Manager). The
available codes are:
Master code
. This code is always enabled and is the only code authorised to enable other users, keys, timed programming and
remote access. It can be used to reset all the other access codes to the factory default (useful if the changed access code is
forgotten).
Installer code
. This code must be enabled each time by the Master code and is automatically deactivated when a new valid
code is entered or a valid key is used. This is to program the system and for maintenance. This code is used by the installer. It
can be used to reset all the other access codes to the factory default (useful if the changed access code is forgotten).
IMPORTANT!
The installer code will be automatically deactivated if any users enter their code while the installer code is
enabled. The same will occur if an electronic or proximity key is used.
User code
. This code must be enabled by the Master code and will remain valid until it is deactivated by the Master code by a
timed programmed control. This code is used by users for normal operations: arming and disarming the system, displaying
system status, reading event log and changing the access code.
Technical Manager code
. This code must be enabled by the Master code and is automatically deactivated when a new valid
code is entered or a valid key is used. It allows to access a limited number of system configuration functions. It can be used to
reset all the other access codes to the factory default (useful if the changed access code is forgotten).
IMPORTANT!
The Technical Manager code will be automatically deactivated if any user enters their code while the Technical
Manager code is enabled. The same will occur if an electronic or proximity key is used.
Each access code is freely programmable with a variable length from a minimum of four to a maximum of six digits. Each user c an
change their access code at will.
IMPORTANT!
Trough the use of the web server only 6-digit codes are allowed.
IMPORTANT!
Any access code shorter than six digits will cancel the EN50131 grade 3 compliance of the entire burglar alarm
system.
If there are no other limiting factors, five or six digit access codes allow EN50131 grade 2 compliance.
Four digit codes will cancel EN50131 compliance.
ADVICE
: All users, including the Master and Installer, should change their code before commissioning the system.
Always press
to confirm the entered access code to access menus or functions.
On MP500/4N, MP500/8 and MP500/16 control panels, starting from control panel SW version 1.01 and starting from keypad SW
version 1.03, if the hold-up function has been enabled (see paragraph 2.1.4
How to enable the hold-up function
), when user code is
modified automaticaly, the system will also assing a code for the hold-up function which is the same as the chosen one + 1 (for
example, if 789456 has been chosen, the hold-up code will be 789457).
IMPORTANT!
Enabling the hold-up function will cancel EN50131 compliance.