MP500/4N-8-16 Programming
4.17 GENERAL SYSTEM PARAMETERS (TIMINGS)
The general system parameters are used to manage alarms and indications. Some of these parameters may be configured.
IMPORTANT!
Specific minimum and maximum values must be respected to ensure EN50131 compliance for the following
parameters.
However, these requirements may be ignored, while maintaining EN50131 compliance, in presence of local police regulations
which require other settings.
T BURGLAR ALARM
: This is the alarm output activation time (e.g. the time for which the sirens sound) for burglar alarms.
Selectable times: 30 / 60 / 90 / 180 seconds and 9 / 15 minutes.
IMPORTANT!
The minimum alarm time for an EN50131 compliant system is 90 seconds.
T PRE-ALARM
: This is the pre-alarm output activation time (e.g. the time for which the sirens sound). Selectable times: 30 / 60 /
90 / 180 seconds and 9 / 15 minutes.
IMPORTANT!
The minimum alarm time for an EN50131 compliant system is 90 seconds.
T EMERGENCY ALAR
: This is the output activation time (e.g. the time for which the sirens sound) for the emergency alarms.
Selectable times: 30 / 60 / 90 / 180 seconds and 9 / 15 minutes.
ALARM COUNT
: This is the number of permitted alarm repetitions also in case of new alarms. DISABLED means that the alarm
indications will be generated at each new event. Selectable values: DISABLED, 2 / 4 / 6 / 8 / 10.
IMPORTANT!
The alarm count must be enabled to ensure EN50131 compliance.
The alarm count is reset at each alarm system activation cycle and at 10:00 every day.
T LACK OF POWER
: this is the time of a mains blackout before generating the no power event. Selectable times: 10 / 30 minutes,
1 hour.
IMPORTANT!
The maximum no power time before generating an alarm must be 1 hour in an EN50131 compliant system.
4.17.1
Programming procedure
Proceed as follows to program the timings:
1) Enter
<Installer code>
, press
, then
and finally
repeatedly until PARAMETERS
appears.
2) Press
.
3) Press
. Press
and
to select the required time. Press
to confirm.
4) Press
.
5) Press
. Press
and
to select the required time. Press
to confirm.
6) Press
.
7) Press
. Press
and
to select the required time. Press
to confirm.
UT00:INSTALLER
PARAMETERS
PARAMETERS
T BURGLAR ALARM
T BURGLAR ALARM
15min
PARAMETERS
T PRE-ALARM
PRE-ALARM
15min
PARAMETERS
T EMERGENCY ALAR
T EMERGENCY ALAR
180s