130
MP500/4N-8-16 Programming
10.4 DETAIL OF EVENTS AND MANAGEMENT
Cause
LED
Log
Mem
ory
Description of the event
(Event Log and
Diagnose Log)
Auxiliary indication
(controlled output)
Telephone message
Keypad
Reader
Burglar alarm
(immediate, delayed, delayed
way, last exit)
■
■
■
Inxxx:name
IN customisation
Burglar
Burglar alarm
Burglar pre-alarm
■
■
■
Inxxx:name
IN customisation
Burglar
Burglar alarm
Panic indication from input /
function key / remote control
■
■
■
“KP xx”
Panic
Panic
Fire indication from input /
function key / remote control
■
■
■
“KP xx”
Fire
Fire alarm
Emergency indication from input
/ function key / remote control
■
■
■
“KP xx”
Emergency
Emergency request
Silent panic indication from input
/ function key / remote control
■
■
“KP xx”
Silent panic
Panic
Technological input / output 1
activation
■
■
■
Inxxx:name
TECHNOL. TYPE 1
Technological 1
Technological service 1
Technological input / output 2
activation
■
■
■
Inxxx:name
TECHNOL. TYPE 2
Technological 2
Technological service 2
Technological input / output 3
activation
■
■
■
Inxxx:name
TECHNOL. TYPE 3
Technological 3
Technological service 3
Low battery
LOW BATTERY
CONTROL PANEL or device
Low battery
Battery fault/restored
Detector fault input alarm
■
Inxxx:name
DETECTOR FAILURE
Detector fault
Anomaly
Siren failure input alarm
■
■
SIREN FAILURE
System failure
Anomaly
Fault input alarm
■
■
Inxxx:name
FAILURE
Failure
Anomaly
Jamming fault input alarm
■
■
Inxxx:name
JAMMING
Detector fault
Anomaly
External communicator fault
input alarm
■
■
Inxxx:name
COM. FAULT
Telephone fault
Anomaly
Other faults
■
System failure
Failure
No communication with device
on bus
■
■
BUS COMM.FAILURE BUS
device (DDxx:name)
Sys fault
System tamper
Isolated inputs
■
Inxxx:name
Isolated inputs
Excluded input
Inhibited inputs (temporarily
during arming)
■
INHIBIT
Isolated inputs
Excluded input
After having entered 21 wrong
codes
■
■
WRONG CODE
device (DDxx:name)
Tamper
Tamper or SAB input indicating
tampering
■
■
device (DDxx:name)
Tamper
System tamper
Balanced input imbalance
■
■
Inxxx:name
IN customisation
Tamper
System tamper
Radio jamming
■
■
JAMMING
device (DDxx:name)
Tamper
Radio tamper
No wireless device supervision
■
■
SUPERVISION
device (DDxx:name)
Tamper
Radio tamper
Enter menu with installer code
■
Open input
■
Inxxx:name
IN customisation
Open input
Test input opening
■
■
Inxxx:name
INPUT OF TEST
Open input
PO warning / arm partitions /
enable-disable user or key /
enable-disable output
■
PO warning
Instantaneous lack of power
*
POWER INSTANT.
(START/END)
"Lack of power" after
programmed timeout
*
■
POWER (START/END)
Lack of power
Power mains
fault/restored
Arm/disarm partitions
■
EXECUTED or PARTIALLY
DONE
Partition status
Armed
Partition xx
Disarmed partition xx
Содержание MP500/16