4-60
Communication Interfaces
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
FC23 Response Packet
describes the bytes contained in an FC23 response packet.
Table 4-13. Packet format for FC23 response
Byte
Numbers
Purpose
Response Value
0 and 1
Transaction ID
Not used (value is copied from send
packet)
2 and 3
Protocol ID
0
4 and 5
Number of
bytes following
Count of bytes in packet, starting with
byte 6
6
Unit ID
0 (copied from send packet; denotes the
default AE Bus address)
7
Function code
23 = 0x17h
8
Byte counter
Not used
9
AE Bus
command
number
AE Bus command number; see
for a complete list of
commands
10
Number of
bytes in AE
Bus response
packet
Total number of bytes in the AE Bus
packet; for a description of the AE Bus
packet, see
; for information on the number
of data bytes in each AE Bus command,
see
11 and up
AE Bus data
bytes
Data bytes contained in the AE Bus
packet; for a description of the data bytes
for each command, see
Note:
Modbus word swapping does not
affect the order of these bytes.
These bytes are ordered as
necessary for the AE Bus
command (least significant bytes
first).
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...