5-18
Installation, Setup, and Operation
CESAR 1312 (E)
Dressler
®
HF-Technik GmbH
1. Select load power regulation mode:
Send one data byte for command
3
(see
).
4
7 = Load power regulation
2. Specify the output set point level for the regulation mode:
Send two data bytes, least significant byte first, for command
8
representing the set point level in watts (see
To Select Load Power Regulation Using the CESAR Generator Front Panel:
Complete the following steps to select P
real
regulation mode using the front
panel:
1. Press the
Program
soft key.
Control Settings
appears on the display.
2. Press
Change
.
3. Press
Control P
real
.
4. Select the desired power set point between 0 W and 1.2 kW using the
RF
POWER
rotary dial knob. Press the
Increm Auto
soft key to toggle
between dynamic increments (Auto) and several fixed increments.
5. Press
Ok
to confirm.
6. Press
Exit
.
7. Press
Execute
.
The operating screen will then display the load power in watts, the reflected
power in watts, and the
Program
and
Display
soft keys.
SETTING EXTERNAL POWER REGULATION MODE (DC
BIAS)
In external power regulation mode, the CESAR Generator regulates RF power
at a constant DC self bias voltage in the plasma chamber. The RF output
power can be limited to protect your plasma chamber against high RF power.
This limitation is useful if there is no self bias voltage in the beginning of the
process.
This section explains how to select external power regulation using the
User
Port
, the
Host
port, or the front panel.
To Select External Power Regulation Through the User Port:
If you are using the 25-pin
User Port
, see pin 8,
If you are using the 15-pin
User Port
, see pin 2,
and
.
Содержание CESAR 1312
Страница 1: ...U s e r M a n u a l s e r v i c e d r e s s l e r c o m CESAR Generator Model 1312 ...
Страница 2: ......
Страница 3: ...User Manual CESAR Generator Model 1312 CESAR 1312 E ...
Страница 6: ...iv CESAR 1312 E Dressler HF Technik GmbH ...
Страница 14: ...xii List of Tables CESAR 1312 E Dressler HF Technik GmbH ...
Страница 24: ...1 10 Safety and Product Compliance Guidelines CESAR 1312 E Dressler HF Technik GmbH ...
Страница 34: ...3 8 Specifications CESAR 1312 E Dressler HF Technik GmbH ...
Страница 170: ...5 50 Installation Setup and Operation CESAR 1312 E Dressler HF Technik GmbH ...
Страница 188: ...6 18 Troubleshooting and Customer Support CESAR 1312 E Dressler HF Technik GmbH ...